{"answers":{"affected":"It affects 13 products.","exploited":"There is no known exploitation of CVE-2020-16216 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-16216 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-16216 is a medium-severity denial of service vulnerability in Philips IntelliVue, published on 11 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-16216 and fix it if it is affected.\n\nWhat it is: CVE-2020-16216 is a medium-severity denial of service vulnerability in Philips IntelliVue, published on 11 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-16216 in the wild and no public exploit code.\n\nAffected product: Philips IntelliVue. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-16216/ (Markdown: https://insights.sbomify.com/CVE-2020-16216/index.md)","id":"CVE-2020-16216","markdown":"https://insights.sbomify.com/CVE-2020-16216/index.md","name":"CVE-2020-16216","record":{"aliases":["GHSA-r3cv-8v59-5mh6"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Patient monitoring devices","requires_auth":"none","summary":"Attackers can cause a denial-of-service condition via improper input validation, leading to system restarts on Philips IntelliVue patient monitors.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"intellivue_mp2-mp90_firmware","vendor":"philips"},{"product":"intellivue_mx100_firmware","vendor":"philips"},{"product":"intellivue_mx400_firmware","vendor":"philips"},{"product":"intellivue_mx550_firmware","vendor":"philips"},{"product":"intellivue_mx600_firmware","vendor":"philips"},{"product":"intellivue_mx700_firmware","vendor":"philips"},{"product":"intellivue_mx750_firmware","vendor":"philips"},{"product":"intellivue_mx800_firmware","vendor":"philips"},{"product":"intellivue_mx850_firmware","vendor":"philips"},{"product":"intellivue_x2_firmware","vendor":"philips"},{"product":"intellivue_x3_firmware","vendor":"philips"},{"product":"patient_information_center_ix","vendor":"philips"},{"product":"performancebridge_focal_point","vendor":"philips"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, \nMX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, \nthe product receives input or data but does not validate or incorrectly \nvalidates that the input has the properties required to process the data\n safely and correctly, which can induce a denial-of-service condition \nthrough a system restart.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Patient Monitoring Devices Improper Input Validation","id":"CVE-2020-16216","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Use after free in Advantech WebAccess HMI Designer","id":"CVE-2020-16217"},"packages":[],"prev":{"headline":"Memory corruption in Advantech WebAccess HMI Designer","id":"CVE-2020-16215"},"products":["IntelliVue","IntelliVue patient monitors"],"published":"2020-09-11","related":[{"cvss_score":6.4,"headline":"Philips Patient Monitoring Devices Improper Check for Certificate Revocation","id":"CVE-2020-16228","kev_date_added":null,"published":"2020-09-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Philips"]},"summary":"Attackers can cause a denial-of-service condition via improper input validation, leading to system restarts on Philips IntelliVue patient monitors.","url":"https://insights.sbomify.com/CVE-2020-16216/"}