{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-16218 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-16218 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-16218 is a low-severity cross-site scripting vulnerability in Philips Patient Information Center iX (PICiX), published on 11 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-16218 and fix it if it is affected.\n\nWhat it is: CVE-2020-16218 is a low-severity cross-site scripting vulnerability in Philips Patient Information Center iX (PICiX), published on 11 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-16218 in the wild and no public exploit code.\n\nAffected product: Philips Patient Information Center iX (PICiX). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-16218/ (Markdown: https://insights.sbomify.com/CVE-2020-16218/index.md)","id":"CVE-2020-16218","markdown":"https://insights.sbomify.com/CVE-2020-16218/index.md","name":"CVE-2020-16218","record":{"aliases":["GHSA-9p4m-gvr2-2mpp"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Patient monitoring device","requires_auth":"low_privilege","summary":"Attackers can inject scripts into patient monitoring web interfaces to steal patient data via cross-site scripting.","user_interaction":"not_required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"patient_information_center_ix","vendor":"philips"}],"cvss":{"score":3.5,"severity":"low","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the \nsoftware does not neutralize or incorrectly neutralizes \nuser-controllable input before it is placed in output that is then used \nas a webpage and served to other users. Successful exploitation could \nlead to unauthorized access to patient data via a read-only web \napplication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Patient Monitoring Devices Cross-site Scripting","id":"CVE-2020-16218","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in Delta Electronics TPEditor","id":"CVE-2020-16219"},"packages":[],"prev":{"headline":"Use after free in Advantech WebAccess HMI Designer","id":"CVE-2020-16217"},"products":["Patient Information Center iX (PICiX)"],"published":"2020-09-11","related":[{"cvss_score":8.8,"headline":"Philips Patient Monitoring Devices Improper Authentication","id":"CVE-2020-16222","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":6.8,"headline":"Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere","id":"CVE-2020-16212","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":6.5,"headline":"Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation","id":"CVE-2021-43548","kev_date_added":null,"published":"2021-12-27"},{"cvss_score":6.5,"headline":"Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency","id":"CVE-2020-16224","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":6.1,"headline":"Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key","id":"CVE-2021-43552","kev_date_added":null,"published":"2021-12-27"},{"cvss_score":5,"headline":"Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV File","id":"CVE-2020-16214","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":4.3,"headline":"Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input","id":"CVE-2020-16220","kev_date_added":null,"published":"2020-09-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Philips"]},"summary":"Attackers can inject scripts into patient monitoring web interfaces to steal patient data via cross-site scripting.","url":"https://insights.sbomify.com/CVE-2020-16218/"}