{"answers":{"affected":"It affects 13 products.","exploited":"There is no known exploitation of CVE-2020-16228 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-16228 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-16228 is a medium-severity vulnerability in Philips IntelliVue X3, published on 11 Sep 2020."},"fix_prompt":"Check this codebase for CVE-2020-16228 and fix it if it is affected.\n\nWhat it is: CVE-2020-16228 is a medium-severity vulnerability in Philips IntelliVue X3, published on 11 Sep 2020. \nExploitation: There is no known exploitation of CVE-2020-16228 in the wild and no public exploit code.\n\nAffected product: Philips IntelliVue X3. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-16228/ (Markdown: https://insights.sbomify.com/CVE-2020-16228/index.md)","id":"CVE-2020-16228","markdown":"https://insights.sbomify.com/CVE-2020-16228/index.md","name":"CVE-2020-16228","record":{"aliases":["GHSA-g25m-mg72-9v2w"],"analysis":null,"analysis_generated_by":null,"assigner":"icscert","cpe":[{"product":"intellivue_mp2-mp90_firmware","vendor":"philips"},{"product":"intellivue_mx100_firmware","vendor":"philips"},{"product":"intellivue_mx400_firmware","vendor":"philips"},{"product":"intellivue_mx550_firmware","vendor":"philips"},{"product":"intellivue_mx600_firmware","vendor":"philips"},{"product":"intellivue_mx700_firmware","vendor":"philips"},{"product":"intellivue_mx750_firmware","vendor":"philips"},{"product":"intellivue_mx800_firmware","vendor":"philips"},{"product":"intellivue_mx850_firmware","vendor":"philips"},{"product":"intellivue_x2_firmware","vendor":"philips"},{"product":"intellivue_x3_firmware","vendor":"philips"},{"product":"patient_information_center_ix","vendor":"philips"},{"product":"performancebridge_focal_point","vendor":"philips"}],"cvss":{"score":6.4,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-299","name":"Improper Check for Certificate Revocation"}],"description":"In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Patient Monitoring Devices Improper Check for Certificate Revocation","id":"CVE-2020-16228","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":null,"year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in Advantech WebAccess HMI Designer","id":"CVE-2020-16229"},"packages":[],"prev":{"headline":"Code injection in Delta Electronics TPEditor","id":"CVE-2020-16227"},"products":["IntelliVue X3","IntelliVue patient monitors","Patient Information Center iX (PICiX)","PerformanceBridge Focal Point"],"published":"2020-09-11","related":[{"cvss_score":6.5,"headline":"Philips Patient Monitoring Devices Improper Input Validation","id":"CVE-2020-16216","kev_date_added":null,"published":"2020-09-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Philips"]},"summary":null,"url":"https://insights.sbomify.com/CVE-2020-16228/"}