{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2020-25154 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-25154 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-25154 is a medium-severity vulnerability in B. Braun Melsungen AG Battery pack with Wi-Fi, published on 14 Apr 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-25154 and fix it if it is affected.\n\nWhat it is: CVE-2020-25154 is a medium-severity vulnerability in B. Braun Melsungen AG Battery pack with Wi-Fi, published on 14 Apr 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-25154 in the wild and no public exploit code.\n\nAffected product: B. Braun Melsungen AG Battery pack with Wi-Fi. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-25154/ (Markdown: https://insights.sbomify.com/CVE-2020-25154/index.md)","id":"CVE-2020-25154","markdown":"https://insights.sbomify.com/CVE-2020-25154/index.md","name":"CVE-2020-25154","record":{"aliases":["GHSA-6f7x-3vm2-cjhw"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical device interface","requires_auth":"none","summary":"Attackers can redirect users to malicious sites via the administrative interface of B. Braun medical devices, potentially facilitating phishing attacks.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"datamodule_compactplus","vendor":"bbraun"},{"product":"spacecom","vendor":"bbraun"}],"cvss":{"score":5.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25154","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"open_redirect","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in NIO 50","id":"CVE-2020-25155"},"packages":[],"prev":{"headline":"MOXA NPort IAW5000A-I/O Series","id":"CVE-2020-25153"},"products":["Battery pack with Wi-Fi","Data module compactplus","SpaceCom"],"published":"2022-04-14","related":[{"cvss_score":7.6,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25150","kev_date_added":null,"published":"2022-04-14"},{"cvss_score":7.6,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25158","kev_date_added":null,"published":"2022-04-14"},{"cvss_score":7.6,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25166","kev_date_added":null,"published":"2022-04-14"},{"cvss_score":7.5,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25162","kev_date_added":null,"published":"2022-04-14"},{"cvss_score":7.2,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25156","kev_date_added":null,"published":"2022-04-14"},{"cvss_score":6.8,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25160","kev_date_added":null,"published":"2022-04-14"},{"cvss_score":6.7,"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-16238","kev_date_added":null,"published":"2022-04-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["B. Braun Melsungen AG"]},"summary":"Attackers can redirect users to malicious sites via the administrative interface of B. Braun medical devices, potentially facilitating phishing attacks.","url":"https://insights.sbomify.com/CVE-2020-25154/"}