{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2020-25165 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-25165 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-25165 is a high-severity authentication bypass vulnerability in BD Alaris PC Unit and BD Alaris Systems Manager, published on 13 Nov 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-25165 and fix it if it is affected.\n\nWhat it is: CVE-2020-25165 is a high-severity authentication bypass vulnerability in BD Alaris PC Unit and BD Alaris Systems Manager, published on 13 Nov 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-25165 in the wild and no public exploit code.\n\nAffected product: BD Alaris PC Unit and BD Alaris Systems Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-25165/ (Markdown: https://insights.sbomify.com/CVE-2020-25165/index.md)","id":"CVE-2020-25165","markdown":"https://insights.sbomify.com/CVE-2020-25165/index.md","name":"CVE-2020-25165","record":{"aliases":["GHSA-mf9g-gpjw-p38r"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical infusion system","requires_auth":"none","summary":"An attacker can cause a denial of service on BD Alaris PC Units by exploiting an authentication vulnerability in network sessions, forcing manual operation.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"alaris_8015_pcu_firmware","vendor":"bd"},{"product":"alaris_systems_manager","vendor":"bd"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manager. If exploited, an attacker could perform a denial-of-service attack on the BD Alaris PC Unit by modifying the configuration headers of data in transit. A denial-of-service attack could lead to a drop in the wireless capability of the BD Alaris PC Unit, resulting in manual operation of the PC Unit.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in BD Alaris PC Unit and BD Alaris Systems Manager","id":"CVE-2020-25165","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25166"},"packages":[],"prev":{"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25164"},"products":["BD Alaris PC Unit and BD Alaris Systems Manager"],"published":"2020-11-13","related":[{"cvss_score":6.8,"headline":"PCU Configuration Lacks Authentication","id":"CVE-2023-30560","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":6.1,"headline":"Lack of Cryptographic Security of IUI Bus","id":"CVE-2023-30561","kev_date_added":null,"published":"2023-07-13"},{"cvss_score":5.2,"headline":"Wireless Card Firmware Improperly Signed","id":"CVE-2023-30559","kev_date_added":null,"published":"2023-07-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can cause a denial of service on BD Alaris PC Units by exploiting an authentication vulnerability in network sessions, forcing manual operation.","url":"https://insights.sbomify.com/CVE-2020-25165/"}