{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2020-25169 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-25169 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-25169 is a high-severity vulnerability in Reolink RLC-4XX series, published on 26 Jan 2021. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-25169 and fix it if it is affected.\n\nWhat it is: CVE-2020-25169 is a high-severity vulnerability in Reolink RLC-4XX series, published on 26 Jan 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-25169 in the wild and no public exploit code.\n\nAffected product: Reolink RLC-4XX series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-25169/ (Markdown: https://insights.sbomify.com/CVE-2020-25169/index.md)","id":"CVE-2020-25169","markdown":"https://insights.sbomify.com/CVE-2020-25169/index.md","name":"CVE-2020-25169","record":{"aliases":["GHSA-69qh-6j8v-ppx3"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Reolink P2P Camera","requires_auth":"none","summary":"Attackers can intercept sensitive camera feed data due to insufficient protection of data transferred between local devices and Reolink servers.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"rlc-410_firmware","vendor":"reolink"},{"product":"rlc-422_firmware","vendor":"reolink"},{"product":"rlc-423_firmware","vendor":"reolink"},{"product":"rlc-423s_firmware","vendor":"reolink"},{"product":"rlc-510a_firmware","vendor":"reolink"},{"product":"rlc-520a_firmware","vendor":"reolink"},{"product":"rln8-410_firmware","vendor":"reolink"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"The affected Reolink P2P products do not sufficiently protect data transferred between the local device and Reolink servers. This can allow an attacker to access sensitive information, such as camera feeds.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Reolink P2P Cameras","id":"CVE-2020-25169","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"B. Braun OnlineSuite","id":"CVE-2020-25170"},"packages":[],"prev":{"headline":"B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus","id":"CVE-2020-25168"},"products":["RLC-4XX series","RLC-5XX series","RLN-X10 series"],"published":"2021-01-26","related":[{"cvss_score":7.8,"headline":"Reolink P2P Cameras","id":"CVE-2020-25173","kev_date_added":null,"published":"2021-01-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Reolink"]},"summary":"Attackers can intercept sensitive camera feed data due to insufficient protection of data transferred between local devices and Reolink servers.","url":"https://insights.sbomify.com/CVE-2020-25169/"}