{"answers":{"affected":"It affects 17 products.","exploited":"There is no known exploitation of CVE-2020-25176 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-25176 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-25176 is a critical path traversal vulnerability in Rockwell Automation ISaGRAF Runtime, published on 18 Mar 2022. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-25176 and fix it if it is affected.\n\nWhat it is: CVE-2020-25176 is a critical path traversal vulnerability in Rockwell Automation ISaGRAF Runtime, published on 18 Mar 2022. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-25176 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation ISaGRAF Runtime. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-25176/ (Markdown: https://insights.sbomify.com/CVE-2020-25176/index.md)","id":"CVE-2020-25176","markdown":"https://insights.sbomify.com/CVE-2020-25176/index.md","name":"CVE-2020-25176","record":{"aliases":["GHSA-fg53-m5qv-8qwq"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"ISaGRAF Runtime","requires_auth":"high_privilege","summary":"Remote unauthenticated attackers can exploit path traversal in ISaGRAF Runtime to achieve remote code execution.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"aadvance_controller","vendor":"rockwellautomation"},{"product":"isagraf_free_runtime","vendor":"rockwellautomation"},{"product":"isagraf_runtime","vendor":"rockwellautomation"},{"product":"micro810_firmware","vendor":"rockwellautomation"},{"product":"micro820_firmware","vendor":"rockwellautomation"},{"product":"micro830_firmware","vendor":"rockwellautomation"},{"product":"micro850_firmware","vendor":"rockwellautomation"},{"product":"micro870_firmware","vendor":"rockwellautomation"},{"product":"easergy_c5_firmware","vendor":"schneider-electric"},{"product":"easergy_t300_firmware","vendor":"schneider-electric"},{"product":"epas_gtw_firmware","vendor":"schneider-electric"},{"product":"micom_c264_firmware","vendor":"schneider-electric"},{"product":"pacis_gtw_firmware","vendor":"schneider-electric"},{"product":"saitel_dp_firmware","vendor":"schneider-electric"},{"product":"saitel_dr_firmware","vendor":"schneider-electric"},{"product":"scd2200_firmware","vendor":"schneider-electric"},{"product":"multismart_firmware","vendor":"xylem"}],"cvss":{"score":9.1,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"},{"id":"CWE-23","name":"Relative Path Traversal"}],"description":"Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal","id":"CVE-2020-25176","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2020"},"n_packages":0,"n_references":4,"next":{"headline":"Memory corruption in WECON PLC Editor","id":"CVE-2020-25177"},"packages":[],"prev":{"headline":"Information disclosure in GE Healthcare Imaging and Ultrasound Products","id":"CVE-2020-25175"},"products":["ISaGRAF Runtime"],"published":"2022-03-18","related":[{"cvss_score":7.8,"headline":"Rockwell Automation ISaGRAF5 Runtime Unprotected Storage of Credentials","id":"CVE-2020-25184","kev_date_added":null,"published":"2022-03-18"},{"cvss_score":7.5,"headline":"Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information","id":"CVE-2020-25178","kev_date_added":null,"published":"2022-03-18"},{"cvss_score":6.7,"headline":"Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element","id":"CVE-2020-25182","kev_date_added":null,"published":"2022-03-18"},{"cvss_score":5.3,"headline":"Rockwell Automation ISaGRAF5 Runtime Use of Hard-coded Cryptographic Key","id":"CVE-2020-25180","kev_date_added":null,"published":"2022-03-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Rockwell Automation"]},"summary":"Remote unauthenticated attackers can exploit path traversal in ISaGRAF Runtime to achieve remote code execution.","url":"https://insights.sbomify.com/CVE-2020-25176/"}