{"answers":{"affected":"It affects 17 products.","exploited":"There is no known exploitation of CVE-2020-25182 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-25182 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-25182 is a medium-severity vulnerability in Rockwell Automation ISaGRAF Runtime, published on 18 Mar 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-25182 and fix it if it is affected.\n\nWhat it is: CVE-2020-25182 is a medium-severity vulnerability in Rockwell Automation ISaGRAF Runtime, published on 18 Mar 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-25182 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation ISaGRAF Runtime. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-25182/ (Markdown: https://insights.sbomify.com/CVE-2020-25182/index.md)","id":"CVE-2020-25182","markdown":"https://insights.sbomify.com/CVE-2020-25182/index.md","name":"CVE-2020-25182","record":{"aliases":["GHSA-f6jg-3f64-ghp3"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ISaGRAF Runtime","requires_auth":"high_privilege","summary":"Local attackers can execute arbitrary code via uncontrolled DLL loading in Rockwell Automation ISaGRAF Runtime on Windows.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"aadvance_controller","vendor":"rockwellautomation"},{"product":"isagraf_free_runtime","vendor":"rockwellautomation"},{"product":"isagraf_runtime","vendor":"rockwellautomation"},{"product":"micro810_firmware","vendor":"rockwellautomation"},{"product":"micro820_firmware","vendor":"rockwellautomation"},{"product":"micro830_firmware","vendor":"rockwellautomation"},{"product":"micro850_firmware","vendor":"rockwellautomation"},{"product":"micro870_firmware","vendor":"rockwellautomation"},{"product":"easergy_c5_firmware","vendor":"schneider-electric"},{"product":"easergy_t300_firmware","vendor":"schneider-electric"},{"product":"epas_gtw_firmware","vendor":"schneider-electric"},{"product":"micom_c264_firmware","vendor":"schneider-electric"},{"product":"pacis_gtw_firmware","vendor":"schneider-electric"},{"product":"saitel_dp_firmware","vendor":"schneider-electric"},{"product":"saitel_dr_firmware","vendor":"schneider-electric"},{"product":"scd2200_firmware","vendor":"schneider-electric"},{"product":"multismart_firmware","vendor":"xylem"}],"cvss":{"score":6.7,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"description":"Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element","id":"CVE-2020-25182","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2020"},"n_packages":0,"n_references":4,"next":{"headline":"Medtronic MyCareLink Smart Improper Authentication","id":"CVE-2020-25183"},"packages":[],"prev":{"headline":"Memory corruption in WECON PLC Editor","id":"CVE-2020-25181"},"products":["ISaGRAF Runtime"],"published":"2022-03-18","related":[{"cvss_score":9.1,"headline":"Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal","id":"CVE-2020-25176","kev_date_added":null,"published":"2022-03-18"},{"cvss_score":7.8,"headline":"Rockwell Automation ISaGRAF5 Runtime Unprotected Storage of Credentials","id":"CVE-2020-25184","kev_date_added":null,"published":"2022-03-18"},{"cvss_score":7.5,"headline":"Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information","id":"CVE-2020-25178","kev_date_added":null,"published":"2022-03-18"},{"cvss_score":5.3,"headline":"Rockwell Automation ISaGRAF5 Runtime Use of Hard-coded Cryptographic Key","id":"CVE-2020-25180","kev_date_added":null,"published":"2022-03-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Rockwell Automation"]},"summary":"Local attackers can execute arbitrary code via uncontrolled DLL loading in Rockwell Automation ISaGRAF Runtime on Windows.","url":"https://insights.sbomify.com/CVE-2020-25182/"}