CVE-2020-25228 Missing authorization in LOGO! 8 BM (incl. SIPLUS variants)
An unauthenticated attacker with network access to port 10005 can gain full control of Siemens LOGO! 8 BM devices.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2020-25228?
CVE-2020-25228 is a critical missing authorization vulnerability in Siemens LOGO! 8 BM (incl. SIPLUS variants), published on 14 Dec 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.
Weakness: CWE-306
Which versions are affected by CVE-2020-25228?
It affects 1 product.
Products include Siemens Logo\! 8 Bm Firmware.
How do I fix CVE-2020-25228?
No fix has been published for CVE-2020-25228 yet. Limit exposure of the affected software until one is available.
Upgrade, and check permissions on every request on the server, not only in the interface. More about Missing authorization.
Is CVE-2020-25228 being exploited?
There is no known exploitation of CVE-2020-25228 in the wild and no public exploit code.
Other vulnerabilities in Siemens LOGO! 8 BM (incl. SIPLUS variants)
- CVE-2020-7593 Memory corruption in LOGO! 8 BM (incl. SIPLUS variants)
- CVE-2020-7589 Missing authorization in LOGO! 8 BM (incl. SIPLUS variants)
- CVE-2020-25234 Hardcoded credentials in LOGO! 8 BM (incl. SIPLUS variants)
- CVE-2020-25229 Weak cryptography in LOGO! 8 BM (incl. SIPLUS variants)
- CVE-2020-25230 Weak cryptography in LOGO! 8 BM (incl. SIPLUS variants)
Sources
Also known as GHSA-ch7j-5vw3-j293.