CVE-2020-26272 Electron vulnerable to ID collision when routing IPC messages to renderers containing OOPIFs
Electron IPC messages may be delivered to the wrong frame, allowing attackers to read or modify data in unintended contexts.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- Available
What is CVE-2020-26272?
CVE-2020-26272 is a medium-severity vulnerability in Electronjs Electron, published on 28 Jan 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
The Electron framework lets users write cross-platform desktop applications using JavaScript, HTML and CSS. In versions of Electron IPC prior to 9.4.0, 10.2.0, 11.1.0, and 12.0.0-beta.9, messages sent from the main process to a subframe in the renderer process, through webContents.sendToFrame, event.reply or when using the remote module, can in some cases be delivered to the wrong frame. If your app uses remote, calls webContents.sendToFrame, or calls event.reply in an IPC message handler then it is impacted by this issue. This has been fixed in versions 9.4.0, 10.2.0, 11.1.0, and 12.0.0-beta.9. There are no known workarounds for this issue.
Weakness: CWE-668
Which versions are affected by CVE-2020-26272?
6 open source packages ship an affected version, including electron. It affects 1 product.
| Package | Affected | Fixed in |
|---|---|---|
electron npm | All versions | 9.4.0 |
electron npm | All versions | 9.4.0 |
electron npm | From 10.0.0 | 10.2.0 |
electron npm | From 10.0.0 | 10.2.0 |
electron npm | From 11.0.0 | 11.1.0 |
electron npm | From 11.0.0 | 11.1.0 |
Products include Electronjs Electron.
How do I fix CVE-2020-26272?
Upgrade electron to a fixed version for your release line: 9.4.0, 10.2.0 or 11.1.0.
Is CVE-2020-26272 being exploited?
There is no known exploitation of CVE-2020-26272 in the wild and no public exploit code.
Other vulnerabilities in Electronjs Electron
- CVE-2017-16151 Chromium Remote Code Execution in electron
- CVE-2018-1000118 Electron protocol handler browser vulnerable to Command Injection
- CVE-2026-34780 Electron: Context Isolation bypass via contextBridge VideoFrame transfer
- CVE-2026-102676 Electron: <webview> can enable Node.js integration in Web Workers despite embedder restrictions
- CVE-2026-102673 Electron drops inherited HTML sandbox restrictions for popups opened through OpenURLFromTab
Sources