{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-27262 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-27262 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-27262 is a medium-severity cross-site scripting vulnerability in Innokas Yhtymä Oy Vital Signs Monitor VC150, published on 8 Jan 2021. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-27262 and fix it if it is affected.\n\nWhat it is: CVE-2020-27262 is a medium-severity cross-site scripting vulnerability in Innokas Yhtymä Oy Vital Signs Monitor VC150, published on 8 Jan 2021. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-27262 in the wild and no public exploit code.\n\nAffected product: Innokas Yhtymä Oy Vital Signs Monitor VC150. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-27262/ (Markdown: https://insights.sbomify.com/CVE-2020-27262/index.md)","id":"CVE-2020-27262","markdown":"https://insights.sbomify.com/CVE-2020-27262/index.md","name":"CVE-2020-27262","record":{"aliases":["GHSA-527m-px5j-w6x7"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Vital Signs Monitor","requires_auth":"low_privilege","summary":"An attacker can inject arbitrary scripts via the filename parameter in the administrative web interface of the Vital Signs Monitor.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"vital_signs_monitor_vc150_firmware","vendor":"innokasmedical"}],"cvss":{"score":5.4,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Innokas Yhtymä Oy Vital Signs Monitor VC150 prior to Version 1.7.15 A stored cross-site scripting (XSS) vulnerability exists in the affected products that allow an attacker to inject arbitrary web script or HTML via the filename parameter to multiple update endpoints of the administrative web interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in Innokas Yhtymä Oy Vital Signs Monitor VC150","id":"CVE-2020-27262","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in GE Digital Industrial Gateway Server","id":"CVE-2020-27263"},"packages":[],"prev":{"headline":"Omron CX-One","id":"CVE-2020-27261"},"products":["Innokas Yhtymä Oy Vital Signs Monitor VC150"],"published":"2021-01-08","related":[{"cvss_score":5.3,"headline":"Code injection in BIGCOMPANYSOFT SOFTWARE PRODUCT","id":"CVE-2020-27260","kev_date_added":null,"published":"2021-01-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can inject arbitrary scripts via the filename parameter in the administrative web interface of the Vital Signs Monitor.","url":"https://insights.sbomify.com/CVE-2020-27262/"}