{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2020-27298 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-27298 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-27298 is a medium-severity command injection vulnerability in Philips Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live, published on 20 Jan 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-27298 and fix it if it is affected.\n\nWhat it is: CVE-2020-27298 is a medium-severity command injection vulnerability in Philips Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live, published on 20 Jan 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-27298 in the wild and no public exploit code.\n\nAffected product: Philips Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-27298/ (Markdown: https://insights.sbomify.com/CVE-2020-27298/index.md)","id":"CVE-2020-27298","markdown":"https://insights.sbomify.com/CVE-2020-27298/index.md","name":"CVE-2020-27298","record":{"aliases":["GHSA-4gc9-p44x-vcgg"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips medical workstation","requires_auth":"none","summary":"Attackers can execute arbitrary OS commands on Philips Interventional Workstations via unsanitized input, posing a critical risk to medical device security.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"coronary_tools","vendor":"philips"},{"product":"dynamic_coronary_roadmap","vendor":"philips"},{"product":"interventional_workspot","vendor":"philips"},{"product":"stentboost_live","vendor":"philips"},{"product":"viewforum","vendor":"philips"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Interventional Workstations OS Command Injection","id":"CVE-2020-27298","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in OPC UA Tunneller","id":"CVE-2020-27299"},"packages":[],"prev":{"headline":"Memory corruption in OPC UA Tunneller","id":"CVE-2020-27297"},"products":["Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live","Interventional Workspot","ViewForum"],"published":"2021-01-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Philips"]},"summary":"Attackers can execute arbitrary OS commands on Philips Interventional Workstations via unsanitized input, posing a critical risk to medical device security.","url":"https://insights.sbomify.com/CVE-2020-27298/"}