{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-27376 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-27376 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-27376 is a high-severity missing authorization vulnerability in n/a, published on 7 Apr 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-27376 and fix it if it is affected.\n\nWhat it is: CVE-2020-27376 is a high-severity missing authorization vulnerability in n/a, published on 7 Apr 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-27376 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-27376/ (Markdown: https://insights.sbomify.com/CVE-2020-27376/index.md)","id":"CVE-2020-27376","markdown":"https://insights.sbomify.com/CVE-2020-27376/index.md","name":"CVE-2020-27376","record":{"aliases":["GHSA-2c3p-6xp9-52hq"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Blood pressure monitor","requires_auth":"none","summary":"An attacker can access the blood pressure monitor's functionality without authentication, potentially reading or modifying health data.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"icheck_connect_bp_monitor_bp_testing_118_firmware","vendor":"drtrustusa"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"Dr Trust USA iCheck Connect BP Monitor BP Testing 118 version 1.2.1 is vulnerable to Missing Authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in n/a","id":"CVE-2020-27376","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2020-27377"},"packages":[],"prev":{"headline":"Server-side request forgery in n/a","id":"CVE-2020-27375"},"products":["n/a"],"published":"2022-04-07","related":[{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2020-27373","kev_date_added":null,"published":"2022-04-07"},{"cvss_score":7.5,"headline":"Other in n/a","id":"CVE-2020-27374","kev_date_added":null,"published":"2022-04-07"},{"cvss_score":6.5,"headline":"Server-side request forgery in n/a","id":"CVE-2020-27375","kev_date_added":null,"published":"2022-04-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2026-07-09","vendors":["n/a"]},"summary":"An attacker can access the blood pressure monitor's functionality without authentication, potentially reading or modifying health data.","url":"https://insights.sbomify.com/CVE-2020-27376/"}