{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-28392 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-28392 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-28392 is a high-severity vulnerability in Siemens SIMARIS configuration, published on 9 Feb 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-28392 and fix it if it is affected.\n\nWhat it is: CVE-2020-28392 is a high-severity vulnerability in Siemens SIMARIS configuration, published on 9 Feb 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-28392 in the wild and no public exploit code.\n\nAffected product: Siemens SIMARIS configuration. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-28392/ (Markdown: https://insights.sbomify.com/CVE-2020-28392/index.md)","id":"CVE-2020-28392","markdown":"https://insights.sbomify.com/CVE-2020-28392/index.md","name":"CVE-2020-28392","record":{"aliases":["GHSA-j599-c89v-j989"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens SIMARIS configuration","requires_auth":"low_privilege","summary":"Incorrect folder permissions during installation allow attackers to gain persistence or escalate privileges on Siemens SIMARIS configuration systems.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simaris_configuration","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"description":"A vulnerability has been identified in SIMARIS configuration (All versions \u003c V4.0.1). During installation to default target folder, incorrect permissions are configured for the application folder and subfolders which could allow an attacker to gain persistence or potentially escalate privileges should a user with elevated credentials log onto the machine.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Misconfiguration in SIMARIS configuration","id":"CVE-2020-28392","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in SCALANCE XM-400, XR-500","id":"CVE-2020-28393"},"packages":[],"prev":{"headline":"Hardcoded credentials in SCALANCE X-200 switch family (incl. SIPLUS NET variants)","id":"CVE-2020-28391"},"products":["SIMARIS configuration"],"published":"2021-02-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"Incorrect folder permissions during installation allow attackers to gain persistence or escalate privileges on Siemens SIMARIS configuration systems.","url":"https://insights.sbomify.com/CVE-2020-28392/"}