{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2020-28398 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-28398 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-28398 is a high-severity vulnerability in Siemens RUGGEDCOM ROX MX5000, published on 10 Dec 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-28398 and fix it if it is affected.\n\nWhat it is: CVE-2020-28398 is a high-severity vulnerability in Siemens RUGGEDCOM ROX MX5000, published on 10 Dec 2024. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-28398 in the wild and no public exploit code.\n\nAffected product: Siemens RUGGEDCOM ROX MX5000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-28398/ (Markdown: https://insights.sbomify.com/CVE-2020-28398/index.md)","id":"CVE-2020-28398","markdown":"https://insights.sbomify.com/CVE-2020-28398/index.md","name":"CVE-2020-28398","record":{"aliases":["GHSA-9982-rc28-7h2w"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"RUGGEDCOM ROX router","requires_auth":"none","summary":"An attacker can trick authenticated users into modifying or reading device configuration via CSRF in the web interface CLI.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.16.0), RUGGEDCOM ROX MX5000RE (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1400 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1500 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1501 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1510 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1511 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1512 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1524 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX1536 (All versions \u003c V2.16.0), RUGGEDCOM ROX RX5000 (All versions \u003c V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to \r\ncross-site request forgery (CSRF).\r\n\r\nThis could allow an attacker to read or modify the device configuration\r\nby tricking an authenticated legitimate user into accessing a malicious link.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in RUGGEDCOM ROX MX5000","id":"CVE-2020-28398","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","id":"CVE-2020-28400"},"packages":[],"prev":{"headline":"Missing authorization in SIMATIC Drive Controller family","id":"CVE-2020-28397"},"products":["RUGGEDCOM ROX MX5000","RUGGEDCOM ROX MX5000RE","RUGGEDCOM ROX RX1400","RUGGEDCOM ROX RX1500","RUGGEDCOM ROX RX1501","RUGGEDCOM ROX RX1510","RUGGEDCOM ROX RX1511","RUGGEDCOM ROX RX1512","RUGGEDCOM ROX RX1524","RUGGEDCOM ROX RX1536","RUGGEDCOM ROX RX5000"],"published":"2024-12-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-12-10","vendors":["Siemens"]},"summary":"An attacker can trick authenticated users into modifying or reading device configuration via CSRF in the web interface CLI.","url":"https://insights.sbomify.com/CVE-2020-28398/"}