{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2020-29031 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-29031 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-29031 is a high-severity vulnerability in Secomea GateManager, published on 15 Feb 2021. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-29031 and fix it if it is affected.\n\nWhat it is: CVE-2020-29031 is a high-severity vulnerability in Secomea GateManager, published on 15 Feb 2021. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-29031 in the wild and no public exploit code.\n\nAffected product: Secomea GateManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-29031/ (Markdown: https://insights.sbomify.com/CVE-2020-29031/index.md)","id":"CVE-2020-29031","markdown":"https://insights.sbomify.com/CVE-2020-29031/index.md","name":"CVE-2020-29031","record":{"aliases":["GHSA-7x7m-6347-w9xm"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Secomea GateManager","requires_auth":"low_privilege","summary":"An authenticated attacker can reset passwords for any user in their domain or sub-domains via an Insecure Direct Object Reference in the GateManager WebUI.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"gatemanager_4250_firmware","vendor":"secomea"},{"product":"gatemanager_4260_firmware","vendor":"secomea"},{"product":"gatemanager_8250_firmware","vendor":"secomea"},{"product":"gatemanager_9250_firmware","vendor":"secomea"}],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"},{"id":"CWE-280","name":"Improper Handling of Insufficient Permissions or Privileges"}],"description":"An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation","id":"CVE-2020-29031","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Add integrity check of GateManager firmware","id":"CVE-2020-29032"},"packages":[],"prev":{"headline":"Insufficient CSRF guards","id":"CVE-2020-29030"},"products":["GateManager"],"published":"2021-02-15","related":[{"cvss_score":9,"headline":"Path traversal in GateManager","id":"CVE-2020-29026","kev_date_added":null,"published":"2021-02-15"},{"cvss_score":7.5,"headline":"GTA URLs issued by LMM WEB API may leak information","id":"CVE-2022-25787","kev_date_added":null,"published":"2022-05-04"},{"cvss_score":5.6,"headline":"Clients may connect to a GateManager with TLS 1.0","id":"CVE-2021-32010","kev_date_added":null,"published":"2022-05-04"},{"cvss_score":5.4,"headline":"Insufficient privilege checks on object access and updates.","id":"CVE-2022-25782","kev_date_added":null,"published":"2022-05-04"},{"cvss_score":5.3,"headline":"Host Header Injection allowing web cache poisoning attacks","id":"CVE-2020-29022","kev_date_added":null,"published":"2021-02-16"},{"cvss_score":5.3,"headline":"Missing HtppOnly and Secure flags","id":"CVE-2020-29024","kev_date_added":null,"published":"2021-02-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Secomea"]},"summary":"An authenticated attacker can reset passwords for any user in their domain or sub-domains via an Insecure Direct Object Reference in the GateManager WebUI.","url":"https://insights.sbomify.com/CVE-2020-29031/"}