{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-29032 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-29032 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-29032 is a high-severity vulnerability in Secomea GateManager, published on 5 Mar 2021. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-29032 and fix it if it is affected.\n\nWhat it is: CVE-2020-29032 is a high-severity vulnerability in Secomea GateManager, published on 5 Mar 2021. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-29032 in the wild and no public exploit code.\n\nAffected product: Secomea GateManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-29032/ (Markdown: https://insights.sbomify.com/CVE-2020-29032/index.md)","id":"CVE-2020-29032","markdown":"https://insights.sbomify.com/CVE-2020-29032/index.md","name":"CVE-2020-29032","record":{"aliases":["GHSA-j4h9-mpww-v94q"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Secomea GateManager","requires_auth":"high_privilege","summary":"An authenticated attacker can upload malicious firmware to Secomea GateManager, leading to remote code execution on the server.","user_interaction":"required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"gatemanager_8250_firmware","vendor":"secomea"}],"cvss":{"score":8.4,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"},{"id":"CWE-494","name":"Download of Code Without Integrity Check"}],"description":"Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Add integrity check of GateManager firmware","id":"CVE-2020-29032","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in n/a","id":"CVE-2020-29040"},"packages":[],"prev":{"headline":"Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation","id":"CVE-2020-29031"},"products":["GateManager"],"published":"2021-03-05","related":[{"cvss_score":10,"headline":"IMPROPER NEUTRALIZATION OF NULL BYTE OR NUL CHARACTER CWE-158","id":"CVE-2020-14500","kev_date_added":null,"published":"2020-08-25"},{"cvss_score":9.8,"headline":"OFF-BY-ONE ERROR CWE-193","id":"CVE-2020-14510","kev_date_added":null,"published":"2020-08-25"},{"cvss_score":8.1,"headline":"OFF-BY-ONE ERROR CWE-193","id":"CVE-2020-14508","kev_date_added":null,"published":"2020-08-25"},{"cvss_score":8.1,"headline":"USE OF PASSWORD HASH WITH INSUFFICIENT COMPUTATIONAL EFFORT CWE-916","id":"CVE-2020-14512","kev_date_added":null,"published":"2020-08-25"},{"cvss_score":3.7,"headline":"GateManager does not enforce strict hostname matching for WEB server","id":"CVE-2021-32004","kev_date_added":null,"published":"2021-11-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Secomea"]},"summary":"An authenticated attacker can upload malicious firmware to Secomea GateManager, leading to remote code execution on the server.","url":"https://insights.sbomify.com/CVE-2020-29032/"}