{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2020-6961 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-6961 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-6961 is a critical vulnerability in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors, published on 24 Jan 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-6961 and fix it if it is affected.\n\nWhat it is: CVE-2020-6961 is a critical vulnerability in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors, published on 24 Jan 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-6961 in the wild and no public exploit code.\n\nAffected product: GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-6961/ (Markdown: https://insights.sbomify.com/CVE-2020-6961/index.md)","id":"CVE-2020-6961","markdown":"https://insights.sbomify.com/CVE-2020-6961/index.md","name":"CVE-2020-6961","record":{"aliases":["GHSA-h5jv-7mvc-m9hg"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical telemetry server","requires_auth":"none","summary":"Attackers can access SSH private keys from configuration files in GE CARESCAPE and ApexPro telemetry systems, enabling unauthorized access.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"apexpro_telemetry_server_firmware","vendor":"gehealthcare"},{"product":"carescape_central_station_mai700_firmware","vendor":"gehealthcare"},{"product":"carescape_central_station_mas700_firmware","vendor":"gehealthcare"},{"product":"carescape_telemetry_server_mp100r_firmware","vendor":"gehealthcare"},{"product":"clinical_information_center_mp100d_firmware","vendor":"gehealthcare"},{"product":"clinical_information_center_mp100r_firmware","vendor":"gehealthcare"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"},{"id":"CWE-256","name":"Plaintext Storage of a Password"}],"description":"In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6961","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Code injection in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6962"},"packages":[],"prev":{"headline":"SQL injection in Honeywell Maxpro VMS \u0026 NVR","id":"CVE-2020-6960"},"products":["GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors"],"published":"2020-01-24","related":[{"cvss_score":10,"headline":"Code injection in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6962","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":10,"headline":"Hardcoded credentials in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6963","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":10,"headline":"Weak cryptography in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6966","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":9.9,"headline":"File upload in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6965","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":8.6,"headline":"Missing authorization in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6964","kev_date_added":null,"published":"2020-01-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can access SSH private keys from configuration files in GE CARESCAPE and ApexPro telemetry systems, enabling unauthorized access.","url":"https://insights.sbomify.com/CVE-2020-6961/"}