{"answers":{"affected":"It affects 9 products.","exploited":"There is no known exploitation of CVE-2020-6965 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-6965 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-6965 is a critical vulnerability in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors, published on 24 Jan 2020. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-6965 and fix it if it is affected.\n\nWhat it is: CVE-2020-6965 is a critical vulnerability in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors, published on 24 Jan 2020. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-6965 in the wild and no public exploit code.\n\nAffected product: GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-6965/ (Markdown: https://insights.sbomify.com/CVE-2020-6965/index.md)","id":"CVE-2020-6965","markdown":"https://insights.sbomify.com/CVE-2020-6965/index.md","name":"CVE-2020-6965","record":{"aliases":["GHSA-36xm-w97x-vmwh"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"GE CARESCAPE Telemetry","requires_auth":"low_privilege","summary":"An authenticated attacker can upload arbitrary files via a crafted update package in GE CARESCAPE telemetry systems, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"apexpro_telemetry_server_firmware","vendor":"gehealthcare"},{"product":"carescape_b450_monitor_firmware","vendor":"gehealthcare"},{"product":"carescape_b650_monitor_firmware","vendor":"gehealthcare"},{"product":"carescape_b850_monitor_firmware","vendor":"gehealthcare"},{"product":"carescape_central_station_mai700_firmware","vendor":"gehealthcare"},{"product":"carescape_central_station_mas700_firmware","vendor":"gehealthcare"},{"product":"carescape_telemetry_server_mp100r_firmware","vendor":"gehealthcare"},{"product":"clinical_information_center_mp100d_firmware","vendor":"gehealthcare"},{"product":"clinical_information_center_mp100r_firmware","vendor":"gehealthcare"}],"cvss":{"score":9.9,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"},{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"}],"description":"In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"File upload in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6965","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Weak cryptography in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6966"},"packages":[],"prev":{"headline":"Missing authorization in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6964"},"products":["GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors"],"published":"2020-01-24","related":[{"cvss_score":10,"headline":"Hardcoded credentials in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6961","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":10,"headline":"Code injection in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6962","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":10,"headline":"Hardcoded credentials in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6963","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":10,"headline":"Weak cryptography in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6966","kev_date_added":null,"published":"2020-01-24"},{"cvss_score":8.6,"headline":"Missing authorization in GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors","id":"CVE-2020-6964","kev_date_added":null,"published":"2020-01-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An authenticated attacker can upload arbitrary files via a crafted update package in GE CARESCAPE telemetry systems, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2020-6965/"}