{"answers":{"affected":"It affects 11 products.","exploited":"There is no known exploitation of CVE-2020-7482 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-7482 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-7482 is a medium-severity cross-site scripting vulnerability in Andover Continuum (All versions), published on 23 Mar 2020. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-7482 and fix it if it is affected.\n\nWhat it is: CVE-2020-7482 is a medium-severity cross-site scripting vulnerability in Andover Continuum (All versions), published on 23 Mar 2020. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-7482 in the wild and no public exploit code.\n\nAffected product: Andover Continuum (All versions). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-7482/ (Markdown: https://insights.sbomify.com/CVE-2020-7482/index.md)","id":"CVE-2020-7482","markdown":"https://insights.sbomify.com/CVE-2020-7482/index.md","name":"CVE-2020-7482","record":{"aliases":["GHSA-8f3h-p8gc-q7vq"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["code_execution","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Andover Continuum","requires_auth":"none","summary":"Reflective Cross-site Scripting in Andover Continuum web server allows attackers to execute scripts in user browsers.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"andover_continuum_5720_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_5740_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9200_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9680_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9702_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9900_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9924_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9940_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9941_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_bcx4040_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_bcx9640_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in Andover Continuum (All versions)","id":"CVE-2020-7482","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)","id":"CVE-2020-7483"},"packages":[],"prev":{"headline":"Cross-site scripting in Andover Continuum (All versions)","id":"CVE-2020-7481"},"products":["Andover Continuum (All versions)"],"published":"2020-03-23","related":[{"cvss_score":9.8,"headline":"Code injection in Andover Continuum (All versions)","id":"CVE-2020-7480","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":6.1,"headline":"Cross-site scripting in Andover Continuum (All versions)","id":"CVE-2020-7481","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":6.1,"headline":"Cross-site scripting in Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702","id":"CVE-2019-6853","kev_date_added":null,"published":"2019-11-20"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Reflective Cross-site Scripting in Andover Continuum web server allows attackers to execute scripts in user browsers.","url":"https://insights.sbomify.com/CVE-2020-7482/"}