{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-7531 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-7531 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-7531 is a high-severity missing authorization vulnerability in SCADAPack 7x Remote Connect V3.6.3.574 and prior., published on 16 Sep 2020. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-7531 and fix it if it is affected.\n\nWhat it is: CVE-2020-7531 is a high-severity missing authorization vulnerability in SCADAPack 7x Remote Connect V3.6.3.574 and prior., published on 16 Sep 2020. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-7531 in the wild and no public exploit code.\n\nAffected product: SCADAPack 7x Remote Connect V3.6.3.574 and prior.. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-7531/ (Markdown: https://insights.sbomify.com/CVE-2020-7531/index.md)","id":"CVE-2020-7531","markdown":"https://insights.sbomify.com/CVE-2020-7531/index.md","name":"CVE-2020-7531","record":{"aliases":["GHSA-q699-f9h8-7v6p"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADAPack Remote Connect","requires_auth":"none","summary":"An attacker can execute arbitrary code by placing executables in a specific folder, affecting SCADAPack 7x Remote Connect users.","user_interaction":"required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"scadapack_7x_remote_connect","vendor":"schneider-electric"}],"cvss":{"score":7.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SCADAPack 7x Remote Connect V3.6.3.574 and prior.","id":"CVE-2020-7531","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Deserialization in SCADAPack x70 Security Administrator V1.2.0 and prior.","id":"CVE-2020-7532"},"packages":[],"prev":{"headline":"Missing authorization in SCADAPack 7x Remote Connect V3.6.3.574 and prior.","id":"CVE-2020-7530"},"products":["SCADAPack 7x Remote Connect V3.6.3.574 and prior."],"published":"2020-09-16","related":[{"cvss_score":8.8,"headline":"Missing authorization in SCADAPack 7x Remote Connect V3.6.3.574 and prior.","id":"CVE-2020-7530","kev_date_added":null,"published":"2020-09-16"},{"cvss_score":7.8,"headline":"Deserialization in SCADAPack 7x Remote Connect V3.6.3.574 and prior.","id":"CVE-2020-7528","kev_date_added":null,"published":"2020-09-16"},{"cvss_score":5.5,"headline":"Path traversal in SCADAPack 7x Remote Connect V3.6.3.574 and prior.","id":"CVE-2020-7529","kev_date_added":null,"published":"2020-09-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can execute arbitrary code by placing executables in a specific folder, affecting SCADAPack 7x Remote Connect users.","url":"https://insights.sbomify.com/CVE-2020-7531/"}