{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2020-7546 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-7546 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-7546 is a medium-severity cross-site scripting vulnerability in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information), published on 1 Dec 2020. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2020-7546 and fix it if it is affected.\n\nWhat it is: CVE-2020-7546 is a medium-severity cross-site scripting vulnerability in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information), published on 1 Dec 2020. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2020-7546 in the wild and no public exploit code.\n\nAffected product: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-7546/ (Markdown: https://insights.sbomify.com/CVE-2020-7546/index.md)","id":"CVE-2020-7546","markdown":"https://insights.sbomify.com/CVE-2020-7546/index.md","name":"CVE-2020-7546","record":{"aliases":["GHSA-xcfh-h8m8-532v"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Monitoring SCADA","requires_auth":"low_privilege","summary":"Cross-site scripting in EcoStruxure and SmartStruxure Power Monitoring SCADA allows attackers to perform actions on behalf of authorized users.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_energy_expert","vendor":"schneider-electric"},{"product":"ecostruxure_power_monitoring_expert","vendor":"schneider-electric"},{"product":"power_manager","vendor":"schneider-electric"},{"product":"powerscada_expert_with_advanced_reporting_and_dashboards","vendor":"schneider-electric"},{"product":"powerscada_operation_with_advanced_reporting_and_dashboards","vendor":"schneider-electric"}],"cvss":{"score":5.4,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)","id":"CVE-2020-7546","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)","id":"CVE-2020-7547"},"packages":[],"prev":{"headline":"Missing authorization in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)","id":"CVE-2020-7545"},"products":["EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)"],"published":"2020-12-01","related":[{"cvss_score":8.8,"headline":"Privilege escalation in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)","id":"CVE-2020-7547","kev_date_added":null,"published":"2020-12-01"},{"cvss_score":7.2,"headline":"Missing authorization in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)","id":"CVE-2020-7545","kev_date_added":null,"published":"2020-12-01"},{"cvss_score":6.1,"headline":"Open redirect in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure\u0026#xaa; Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure\u0026#xaa; Energy Expert 1.3 (formerly Power Manager), EcoStruxure\u0026#xaa; Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure\u0026#xaa; Power Monitoring Expert (PME) v9.0, EcoStruxure\u0026#xaa; Energy Expert v2.0, and EcoStruxure\u0026#xaa;Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module","id":"CVE-2018-7797","kev_date_added":null,"published":"2018-12-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Cross-site scripting in EcoStruxure and SmartStruxure Power Monitoring SCADA allows attackers to perform actions on behalf of authorized users.","url":"https://insights.sbomify.com/CVE-2020-7546/"}