{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-8101 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-8101 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-8101 is a medium-severity command injection vulnerability in ADT LifeShield DIY HD Video Doorbell, published on 2 Feb 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-8101 and fix it if it is affected.\n\nWhat it is: CVE-2020-8101 is a medium-severity command injection vulnerability in ADT LifeShield DIY HD Video Doorbell, published on 2 Feb 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-8101 in the wild and no public exploit code.\n\nAffected product: ADT LifeShield DIY HD Video Doorbell. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-8101/ (Markdown: https://insights.sbomify.com/CVE-2020-8101/index.md)","id":"CVE-2020-8101","markdown":"https://insights.sbomify.com/CVE-2020-8101/index.md","name":"CVE-2020-8101","record":{"aliases":["GHSA-v354-qw54-4f78"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Video Doorbell","requires_auth":"none","summary":"An attacker on the same network can execute arbitrary commands on the ADT LifeShield DIY HD Video Doorbell due to unsanitized input in the HTTP interface.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Bitdefender","cpe":[{"product":"lifeshield_diy_hd_video_doorbell_firmware","vendor":"adt"}],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in HTTP interface of ADT LifeShield DIY HD Video Doorbell allows an attacker on the same network to execute commands on the device. This issue affects: ADT LifeShield DIY HD Video Doorbell version 1.0.02R09 and prior versions.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command execution due to unsanitized input in LifeShield DIY HD Video Doorbell","id":"CVE-2020-8101","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Insufficient URL sanitization and validation in Safepay Browser (VA-8631)","id":"CVE-2020-8102"},"packages":[],"prev":{"headline":"Incomplete validation in detection code in Bitdefender Engines (VA-8589)","id":"CVE-2020-8100"},"products":["LifeShield DIY HD Video Doorbell"],"published":"2021-02-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["ADT"]},"summary":"An attacker on the same network can execute arbitrary commands on the ADT LifeShield DIY HD Video Doorbell due to unsanitized input in the HTTP interface.","url":"https://insights.sbomify.com/CVE-2020-8101/"}