{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-0202 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-0202 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-0202 is a high-severity denial of service vulnerability in Juniper Junos, published on 15 Jan 2021. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-0202 and fix it if it is affected.\n\nWhat it is: CVE-2021-0202 is a high-severity denial of service vulnerability in Juniper Junos, published on 15 Jan 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-0202 in the wild and no public exploit code.\n\nAffected product: Juniper Junos. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-0202/ (Markdown: https://insights.sbomify.com/CVE-2021-0202/index.md)","id":"CVE-2021-0202","markdown":"https://insights.sbomify.com/CVE-2021-0202/index.md","name":"CVE-2021-0202","record":{"aliases":["GHSA-ggwm-qq5r-j28w"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":true,"product_category":"Juniper network router","requires_auth":"none","summary":"A memory leak in Junos OS on specific routers causes MPC restarts and traffic interruption when IRB interfaces are mapped to VPLS or Bridge-Domains.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"juniper","cpe":[{"product":"junos","vendor":"juniper"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-401","name":"Missing Release of Memory after Effective Lifetime"},{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"On Juniper Networks MX Series and EX9200 Series platforms with Trio-based MPC (Modular Port Concentrator) where Integrated Routing and Bridging (IRB) interface is configured and it is mapped to a VPLS instance or a Bridge-Domain, certain network events at Customer Edge (CE) device may cause memory leak in the MPC which can cause an out of memory and MPC restarts. When this issue occurs, there will be temporary traffic interruption until the MPC is restored. An administrator can use the following CLI command to monitor the status of memory usage level of the MPC: user@device\u003e show system resource-monitor fpc FPC Resource Usage Summary Free Heap Mem Watermark : 20 % Free NH Mem Watermark : 20 % Free Filter Mem Watermark : 20 % * - Watermark reached Slot # % Heap Free RTT Average RTT 1 87 PFE # % ENCAP mem Free % NH mem Free % FW mem Free 0 NA 88 99 1 NA 89 99 When the issue is occurring, the value of “% NH mem Free” will go down until the MPC restarts. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). Please refer to https://kb.juniper.net/KB25385 for the list of Trio-based PFEs. This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3R3-S8; 17.4R3-S2; 18.2R3-S4, 18.2R3-S5; 18.3R3-S2, 18.3R3-S3; 18.4 versions starting from 18.4R3-S1 and later versions prior to 18.4R3-S6; 19.2 versions starting from 19.2R2 and later versions prior to 19.2R3-S1; 19.4 versions starting from 19.4R2 and later versions prior to 19.4R2-S3, 19.4R3; 20.2 versions starting from 20.2R1 and later versions prior to 20.2R1-S3, 20.2R2. This issue does not affect Juniper Networks Junos OS: 18.1, 19.1, 19.3, 20.1.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Junos OS","id":"CVE-2021-0202","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"juniper:junos","products":["juniper:junos"],"type":"denial_of_service","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Junos OS: EX and QFX5K Series: Storm Control does not work as expected when Redundant Trunk Group is configured","id":"CVE-2021-0203"},"packages":[],"prev":{"headline":"Memory corruption in Intel(R) Ethernet 700 Series Controllers","id":"CVE-2021-0200"},"products":["Junos OS"],"published":"2021-01-15","related":[{"cvss_score":9.8,"headline":"Juniper Junos OS EX Series and SRX Series PHP External Variable Modification","id":"CVE-2023-36845","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":8.8,"headline":"Juniper Junos OS Path Traversal","id":"CVE-2020-1631","kev_date_added":"2022-03-25","published":"2020-05-04"},{"cvss_score":6.7,"headline":"Juniper Junos OS Improper Isolation or Compartmentalization","id":"CVE-2025-21590","kev_date_added":"2025-03-13","published":"2025-03-12"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36851","kev_date_added":"2023-11-13","published":"2023-09-26"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series PHP External Variable Modification","id":"CVE-2023-36844","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36846","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series Missing Authentication for Critical Function","id":"CVE-2023-36847","kev_date_added":"2023-11-13","published":"2023-08-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Juniper Networks"]},"summary":"A memory leak in Junos OS on specific routers causes MPC restarts and traffic interruption when IRB interfaces are mapped to VPLS or Bridge-Domains.","url":"https://insights.sbomify.com/CVE-2021-0202/"}