{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-0224 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-0224 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-0224 is a medium-severity denial of service vulnerability in Juniper Junos, published on 22 Apr 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-0224 and fix it if it is affected.\n\nWhat it is: CVE-2021-0224 is a medium-severity denial of service vulnerability in Juniper Junos, published on 22 Apr 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-0224 in the wild and no public exploit code.\n\nAffected product: Juniper Junos. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-0224/ (Markdown: https://insights.sbomify.com/CVE-2021-0224/index.md)","id":"CVE-2021-0224","markdown":"https://insights.sbomify.com/CVE-2021-0224/index.md","name":"CVE-2021-0224","record":{"aliases":["GHSA-m9hm-283g-g7rx"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Junos OS","requires_auth":"none","summary":"An attacker can cause a Denial of Service by spoofing subscriber nodes to exceed the maximum-discovery-table-entries limit, crashing the ANCPD daemon.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"juniper","cpe":[{"product":"junos","vendor":"juniper"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-770","name":"Allocation of Resources Without Limits or Throttling"}],"description":"A vulnerability in the handling of internal resources necessary to bring up a large number of Layer 2 broadband remote access subscriber (BRAS) nodes in Juniper Networks Junos OS can cause the Access Node Control Protocol daemon (ANCPD) to crash and restart, leading to a Denial of Service (DoS) condition. Continued processing of spoofed subscriber nodes will create a sustained Denial of Service (DoS) condition. When the number of subscribers attempting to connect exceeds the configured maximum-discovery-table-entries value, the subscriber fails to map to an internal neighbor entry, causing the ANCPD process to crash. This issue affects Juniper Networks Junos OS: All versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R3-S1; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2; 20.3 versions prior to 20.3R2.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Junos OS: ANCPD core when hitting maximum-discovery-table-entries limit","id":"CVE-2021-0224","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"juniper:junos","products":["juniper:junos"],"type":"denial_of_service","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Junos OS Evolved: Stateless IP firewall filter does not work as expected","id":"CVE-2021-0225"},"packages":[],"prev":{"headline":"Junos OS: telnetd.real Local Privilege Escalation vulnerabilities in SUID binaries","id":"CVE-2021-0223"},"products":["Junos OS"],"published":"2021-04-22","related":[{"cvss_score":9.8,"headline":"Juniper Junos OS EX Series and SRX Series PHP External Variable Modification","id":"CVE-2023-36845","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":8.8,"headline":"Juniper Junos OS Path Traversal","id":"CVE-2020-1631","kev_date_added":"2022-03-25","published":"2020-05-04"},{"cvss_score":6.7,"headline":"Juniper Junos OS Improper Isolation or Compartmentalization","id":"CVE-2025-21590","kev_date_added":"2025-03-13","published":"2025-03-12"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36851","kev_date_added":"2023-11-13","published":"2023-09-26"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series PHP External Variable Modification","id":"CVE-2023-36844","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36846","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series Missing Authentication for Critical Function","id":"CVE-2023-36847","kev_date_added":"2023-11-13","published":"2023-08-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Juniper Networks"]},"summary":"An attacker can cause a Denial of Service by spoofing subscriber nodes to exceed the maximum-discovery-table-entries limit, crashing the ANCPD daemon.","url":"https://insights.sbomify.com/CVE-2021-0224/"}