CVE-2021-21510 Open redirect in Integrated Dell Remote Access Controller (iDRAC)

Medium 6.1 Published Updated

Remote attackers can inject Host headers to poison web caches or trigger redirections in Dell iDRAC8 devices.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
A user has to click or open something
Fix
None listed

What is CVE-2021-21510?

CVE-2021-21510 is a medium-severity vulnerability in Integrated Dell Remote Access Controller (iDRAC), published on 8 Mar 2021. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.

Official description

Dell iDRAC8 versions prior to 2.75.100.75 contain a host header injection vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability by injecting arbitrary ‘Host’ header values to poison a web-cache or trigger redirections.

Weakness: CWE-74, CWE-20

Which versions are affected by CVE-2021-21510?

It affects 1 product.

Products include Dell Idrac8 Firmware.

How do I fix CVE-2021-21510?

No fix has been published for CVE-2021-21510 yet. Limit exposure of the affected software until one is available.

Is CVE-2021-21510 being exploited?

There is no known exploitation of CVE-2021-21510 in the wild and no public exploit code.

Sources

Also known as GHSA-xxm9-gr2r-5m67.

Is CVE-2021-21510 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.