{"answers":{"affected":"It affects 10 products.","exploited":"There is no known exploitation of CVE-2021-22701 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-22701 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-22701 is a medium-severity vulnerability in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), published on 19 Feb 2021. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2021-22701 and fix it if it is affected.\n\nWhat it is: CVE-2021-22701 is a medium-severity vulnerability in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), published on 19 Feb 2021. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2021-22701 in the wild and no public exploit code.\n\nAffected product: PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-22701/ (Markdown: https://insights.sbomify.com/CVE-2021-22701/index.md)","id":"CVE-2021-22701","markdown":"https://insights.sbomify.com/CVE-2021-22701/index.md","name":"CVE-2021-22701","record":{"aliases":["GHSA-f3x2-w4cq-5v25"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"PowerLogic ION devices","requires_auth":"high_privilege","summary":"Cross-site request forgery in PowerLogic ION devices allows attackers to force users to perform unintended actions via the web interface.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"powerlogic_ion7400_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion7650_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion8300_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion8400_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion8500_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion8600_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion8650_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion8800_firmware","vendor":"schneider-electric"},{"product":"powerlogic_ion9000_firmware","vendor":"schneider-electric"},{"product":"powerlogic_pm8000_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.1,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)","id":"CVE-2021-22701","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)","id":"CVE-2021-22702"},"packages":[],"prev":{"headline":"Denial of service in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1","id":"CVE-2021-22699"},"products":["PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)"],"published":"2021-02-19","related":[{"cvss_score":9.8,"headline":"Memory corruption in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)","id":"CVE-2021-22714","kev_date_added":null,"published":"2021-03-11"},{"cvss_score":8.8,"headline":"Information disclosure in PowerLogic PM8000","id":"CVE-2022-46680","kev_date_added":null,"published":"2023-05-22"},{"cvss_score":5.9,"headline":"Information disclosure in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)","id":"CVE-2021-22703","kev_date_added":null,"published":"2021-02-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-29","vendors":["n/a"]},"summary":"Cross-site request forgery in PowerLogic ION devices allows attackers to force users to perform unintended actions via the web interface.","url":"https://insights.sbomify.com/CVE-2021-22701/"}