CVE-2021-22706 Cross-site scripting in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )

Medium 6.1 Published Updated

Cross-site scripting in EVlink charging stations allows attackers to impersonate administrators and perform actions on their behalf.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
A user has to click or open something
Fix
None listed

What is CVE-2021-22706?

CVE-2021-22706 is a medium-severity cross-site scripting vulnerability in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ), published on 21 Jul 2021. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.

Official description

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

Weakness: CWE-79

Which versions are affected by CVE-2021-22706?

It affects 6 products.

Products include Schneider-Electric Evlink City Evc1s22p4 Firmware, Schneider-Electric Evlink City Evc1s7p4 Firmware, Schneider-Electric Evlink Parking Ev.2 Firmware, Schneider-Electric Evlink Parking Evf2 Firmware, Schneider-Electric Evlink Parking Evw2 Firmware, Schneider-Electric Evlink Smart Wallbox Evb1a Firmware.

How do I fix CVE-2021-22706?

No fix has been published for CVE-2021-22706 yet. Limit exposure of the affected software until one is available.

Escape output for the context it lands in and set a strict Content Security Policy. Upgrading the affected component is the real fix. More about Cross-site scripting.

Is CVE-2021-22706 being exploited?

There is no known exploitation of CVE-2021-22706 in the wild and no public exploit code.

Sources

Also known as GHSA-cwj4-vhgq-c4jr.

Is CVE-2021-22706 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free