{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-22804 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-22804 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-22804 is a high-severity path traversal vulnerability in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior), published on 11 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-22804 and fix it if it is affected.\n\nWhat it is: CVE-2021-22804 is a high-severity path traversal vulnerability in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior), published on 11 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-22804 in the wild and no public exploit code.\n\nAffected product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-22804/ (Markdown: https://insights.sbomify.com/CVE-2021-22804/index.md)","id":"CVE-2021-22804","markdown":"https://insights.sbomify.com/CVE-2021-22804/index.md","name":"CVE-2021-22804","record":{"aliases":["GHSA-v99q-86vr-vhgp"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA Data Collector","requires_auth":"none","summary":"An attacker can read arbitrary files on the system running the IGSS Data Collector due to improper validation of network message paths.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"interactive_graphical_scada_system_data_collector","vendor":"schneider-electric"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","id":"CVE-2021-22804","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","id":"CVE-2021-22805"},"packages":[],"prev":{"headline":"File upload in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","id":"CVE-2021-22803"},"products":["Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)"],"published":"2022-02-11","related":[{"cvss_score":9.8,"headline":"Memory corruption in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","id":"CVE-2021-22802","kev_date_added":null,"published":"2022-02-11"},{"cvss_score":9.8,"headline":"File upload in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","id":"CVE-2021-22803","kev_date_added":null,"published":"2022-02-11"},{"cvss_score":9.1,"headline":"Missing authorization in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)","id":"CVE-2021-22805","kev_date_added":null,"published":"2022-02-11"},{"cvss_score":9.1,"headline":"Missing authorization in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)","id":"CVE-2021-22823","kev_date_added":null,"published":"2022-02-11"},{"cvss_score":7.5,"headline":"Denial of service in Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)","id":"CVE-2021-22824","kev_date_added":null,"published":"2022-02-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"An attacker can read arbitrary files on the system running the IGSS Data Collector due to improper validation of network message paths.","url":"https://insights.sbomify.com/CVE-2021-22804/"}