# CVE-2021-22815: Information disclosure in n/a

> An attacker can access the troubleshooting archive on APC Network Management Cards, potentially exposing sensitive configuration or diagnostic data.

- **Severity:** Medium 5.3 (`CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N`)
- **Exploited in the wild:** Not known
- **Login needed:** Not needed
- **Attackable:** Over the internet
- **Victim action needed:** Not needed
- **Fix available:** No
- **Published:** 28 Jan 2022
- **Updated:** 3 Aug 2024
- **Also known as:** GHSA-8rfr-9f7v-chvx

## What is CVE-2021-22815?

CVE-2021-22815 is a medium-severity vulnerability in n/a, published on 28 Jan 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.

### Official description

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Weakness: CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor)

## Which versions are affected by CVE-2021-22815?

It affects 2 products.


Products: Schneider-Electric Network Management Card 2 Firmware, Schneider-Electric Network Management Card 3 Firmware.

## How do I fix CVE-2021-22815?

No fix has been published for CVE-2021-22815 yet. Limit exposure of the affected software until one is available.

## Is CVE-2021-22815 being exploited?

There is no known exploitation of CVE-2021-22815 in the wild and no public exploit code.

## Other vulnerabilities in n/a

- [CVE-2021-22810](https://insights.sbomify.com/CVE-2021-22810/): Cross-site scripting in n/a (medium 6.1)
- [CVE-2021-22811](https://insights.sbomify.com/CVE-2021-22811/): Cross-site scripting in n/a (medium 6.1)
- [CVE-2021-22812](https://insights.sbomify.com/CVE-2021-22812/): Cross-site scripting in n/a (medium 6.1)
- [CVE-2021-22813](https://insights.sbomify.com/CVE-2021-22813/): Cross-site scripting in n/a (medium 6.1)
- [CVE-2021-22814](https://insights.sbomify.com/CVE-2021-22814/): Cross-site scripting in n/a (medium 6.1)

## Fix prompt for AI coding agents

```text
Check this codebase for CVE-2021-22815 and fix it if it is affected.

What it is: CVE-2021-22815 is a medium-severity vulnerability in n/a, published on 28 Jan 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.
Exploitation: There is no known exploitation of CVE-2021-22815 in the wild and no public exploit code.

Affected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.

Task:
1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.
2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.
3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.
4. Run the tests and summarise what changed and why.
5. If nothing in the project is affected, say so and change nothing.

Reference: https://insights.sbomify.com/CVE-2021-22815/ (Markdown: https://insights.sbomify.com/CVE-2021-22815/index.md)
```

## Sources

- CVE record: https://www.cve.org/CVERecord?id=CVE-2021-22815
- NVD: https://nvd.nist.gov/vuln/detail/CVE-2021-22815
- OSV: https://osv.dev/vulnerability/CVE-2021-22815

---
From sbomify Insights: https://insights.sbomify.com/CVE-2021-22815/
Summaries are generated and may contain mistakes; the official description above is the record.