{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2021-23862 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-23862 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-23862 is a high-severity command injection vulnerability in Bosch BVMS, published on 8 Dec 2021. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-23862 and fix it if it is affected.\n\nWhat it is: CVE-2021-23862 is a high-severity command injection vulnerability in Bosch BVMS, published on 8 Dec 2021. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-23862 in the wild and no public exploit code.\n\nAffected product: Bosch BVMS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-23862/ (Markdown: https://insights.sbomify.com/CVE-2021-23862/index.md)","id":"CVE-2021-23862","markdown":"https://insights.sbomify.com/CVE-2021-23862/index.md","name":"CVE-2021-23862","record":{"aliases":["GHSA-6226-9vg7-r4w4"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Bosch video management","requires_auth":"high_privilege","summary":"An authenticated administrator can execute arbitrary system commands via a crafted configuration packet in Bosch video management systems.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"bosch","cpe":[{"product":"bosch_video_management_system","vendor":"bosch"},{"product":"video_recording_manager","vendor":"bosch"},{"product":"videojet_decoder_7513_firmware","vendor":"bosch"},{"product":"videojet_decoder_8000_firmware","vendor":"bosch"}],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Authenticated Remote Code Execution","id":"CVE-2021-23862","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2021-23863"},"packages":[],"prev":{"headline":"Possible Access to Debug Functions in Bosch VRM / BVMS","id":"CVE-2021-23861"},"products":["BVMS","DIVAR IP 7000 R2","DIVAR IP all-in-one 5000","DIVAR IP all-in-one 7000","VJD-7513","VJD-8000","VRM"],"published":"2021-12-08","related":[{"cvss_score":7.4,"headline":"Information disclosure in BVMS","id":"CVE-2022-32540","kev_date_added":null,"published":"2022-09-30"},{"cvss_score":6.5,"headline":"Possible Access to Debug Functions in Bosch VRM / BVMS","id":"CVE-2021-23861","kev_date_added":null,"published":"2021-12-08"},{"cvss_score":5,"headline":"Reflected Cross Site Scripting (XSS) vulnerability in Bosch VRM / BVMS","id":"CVE-2021-23860","kev_date_added":null,"published":"2021-12-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Bosch"]},"summary":"An authenticated administrator can execute arbitrary system commands via a crafted configuration packet in Bosch video management systems.","url":"https://insights.sbomify.com/CVE-2021-23862/"}