{"answers":{"affected":"It affects 11 products.","exploited":"There is no known exploitation of CVE-2021-27456 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-27456 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-27456 is a low-severity vulnerability in Philips GEMINI LXL, published on 23 Mar 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-27456 and fix it if it is affected.\n\nWhat it is: CVE-2021-27456 is a low-severity vulnerability in Philips GEMINI LXL, published on 23 Mar 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-27456 in the wild and no public exploit code.\n\nAffected product: Philips GEMINI LXL. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-27456/ (Markdown: https://insights.sbomify.com/CVE-2021-27456/index.md)","id":"CVE-2021-27456","markdown":"https://insights.sbomify.com/CVE-2021-27456/index.md","name":"CVE-2021-27456","record":{"aliases":["GHSA-r7hh-jqhx-m5xr"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical imaging software","requires_auth":"none","summary":"Attackers can access sensitive patient data stored on removable media without authentication due to lack of access controls in Philips PET/CT software.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"gemini_882160_firmware","vendor":"phillips"},{"product":"gemini_882300_firmware","vendor":"phillips"},{"product":"gemini_882390_firmware","vendor":"phillips"},{"product":"gemini_882400_firmware","vendor":"phillips"},{"product":"gemini_882410_firmware","vendor":"phillips"},{"product":"gemini_882412_firmware","vendor":"phillips"},{"product":"gemini_882470_firmware","vendor":"phillips"},{"product":"gemini_882471_firmware","vendor":"phillips"},{"product":"gemini_882473_firmware","vendor":"phillips"},{"product":"gemini_882476_firmware","vendor":"phillips"},{"product":"truflight_882438_firmware","vendor":"phillips"}],"cvss":{"score":2.4,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-922","name":"Insecure Storage of Sensitive Information"},{"id":"CWE-921","name":"Storage of Sensitive Data in a Mechanism without Access Control"}],"description":"Philips Gemini PET/CT family software stores sensitive information in a removable media device that does not have built-in access control.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Gemini PET/CT Storage of Sensitive Data in a Mechanism Without Access Control","id":"CVE-2021-27456","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2021"},"n_packages":0,"n_references":2,"next":{"headline":"Weak cryptography in Emerson Rosemount X-STREAM Gas Analyzer","id":"CVE-2021-27457"},"packages":[],"prev":{"headline":"Information disclosure in Delta Electronics DOPSoft","id":"CVE-2021-27455"},"products":["GEMINI LXL","Gemini 16 Slice","Gemini Dual","Gemini GXL 10 Slice","Gemini GXL 16 Slice","Gemini GXL 6 Slice","Gemini TF 16 w/ TOF Performance","Gemini TF 64 w/ TOF Performance","Gemini TF Big Bore","Gemini TF Ready","TruFlight Select PET/CT"],"published":"2022-03-23","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Philips"]},"summary":"Attackers can access sensitive patient data stored on removable media without authentication due to lack of access controls in Philips PET/CT software.","url":"https://insights.sbomify.com/CVE-2021-27456/"}