{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-32002 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-32002 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-32002 is a medium-severity missing authorization vulnerability in Secomea SiteManager, published on 5 Aug 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-32002 and fix it if it is affected.\n\nWhat it is: CVE-2021-32002 is a medium-severity missing authorization vulnerability in Secomea SiteManager, published on 5 Aug 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-32002 in the wild and no public exploit code.\n\nAffected product: Secomea SiteManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-32002/ (Markdown: https://insights.sbomify.com/CVE-2021-32002/index.md)","id":"CVE-2021-32002","markdown":"https://insights.sbomify.com/CVE-2021-32002/index.md","name":"CVE-2021-32002","record":{"aliases":["GHSA-g48h-ph99-79xp"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Secomea SiteManager","requires_auth":"none","summary":"Local attackers can access Secomea SiteManager web services without credentials to view network configuration and information.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"sitemanager_firmware","vendor":"secomea"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Improper Access Control vulnerability in web service of Secomea SiteManager allows local attacker without credentials to gather network information and configuration of the SiteManager. This issue affects: Secomea SiteManager All versions prior to 9.5 on Hardware.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SiteManager troubleshooter allows access without authentication from local network","id":"CVE-2021-32002","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Configuration service port remains open 10 minutes after reboot even when already provisioned","id":"CVE-2021-32003"},"packages":[],"prev":{"headline":"K3s/RKE2 bootstrap data is encrypted with empty string if user does not supply a token","id":"CVE-2021-32001"},"products":["SiteManager"],"published":"2021-08-05","related":[{"cvss_score":9.1,"headline":"Reject Remote Management via Cellular UPLINK2","id":"CVE-2020-29020","kev_date_added":null,"published":"2021-03-05"},{"cvss_score":8,"headline":"Configuration service port remains open 10 minutes after reboot even when already provisioned","id":"CVE-2021-32003","kev_date_added":null,"published":"2021-08-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Secomea"]},"summary":"Local attackers can access Secomea SiteManager web services without credentials to view network configuration and information.","url":"https://insights.sbomify.com/CVE-2021-32002/"}