{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-32006 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-32006 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-32006 is a medium-severity missing authorization vulnerability in Secomea GateManager, published on 7 Mar 2022. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-32006 and fix it if it is affected.\n\nWhat it is: CVE-2021-32006 is a medium-severity missing authorization vulnerability in Secomea GateManager, published on 7 Mar 2022. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-32006 in the wild and no public exploit code.\n\nAffected product: Secomea GateManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-32006/ (Markdown: https://insights.sbomify.com/CVE-2021-32006/index.md)","id":"CVE-2021-32006","markdown":"https://insights.sbomify.com/CVE-2021-32006/index.md","name":"CVE-2021-32006","record":{"aliases":["GHSA-xf56-6gfr-p968"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Secomea GateManager","requires_auth":"low_privilege","summary":"Logged-in LinkManager users can access stored SiteManager backup files due to missing authorization checks in the web portal.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"gatemanager","vendor":"secomea"}],"cvss":{"score":5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"},{"id":"CWE-275","name":null},{"id":"CWE-274","name":"Improper Handling of Insufficient Privileges"}],"description":"This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"GateManager information leak for LinkManager Users","id":"CVE-2021-32006","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Missing security header: Referrer-Policy URL","id":"CVE-2021-32007"},"packages":[],"prev":{"headline":"SiteManager Log View XSS Issue","id":"CVE-2021-32005"},"products":["GateManager"],"published":"2022-03-07","related":[{"cvss_score":9.9,"headline":"Logged-in Administrator may get unrestricted file system access","id":"CVE-2021-32008","kev_date_added":null,"published":"2022-03-04"},{"cvss_score":8.7,"headline":"Insufficient validation of plugin files","id":"CVE-2022-38123","kev_date_added":null,"published":"2022-12-06"},{"cvss_score":6.1,"headline":"Clear-text passwords in configuration files","id":"CVE-2022-4308","kev_date_added":null,"published":"2023-04-19"},{"cvss_score":5.5,"headline":"Potential vulnerabilities in GM login process","id":"CVE-2022-2752","kev_date_added":null,"published":"2022-12-09"},{"cvss_score":5,"headline":"Missing XSS guards on firmware page","id":"CVE-2021-32009","kev_date_added":null,"published":"2022-03-11"},{"cvss_score":4.9,"headline":"GateManager debug interface is included in non-debug builds","id":"CVE-2023-0317","kev_date_added":null,"published":"2023-04-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Secomea"]},"summary":"Logged-in LinkManager users can access stored SiteManager backup files due to missing authorization checks in the web portal.","url":"https://insights.sbomify.com/CVE-2021-32006/"}