{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2021-33846 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-33846 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-33846 is a medium-severity vulnerability in Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard), published on 21 Jan 2022. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-33846 and fix it if it is affected.\n\nWhat it is: CVE-2021-33846 is a medium-severity vulnerability in Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard), published on 21 Jan 2022. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-33846 in the wild and no public exploit code.\n\nAffected product: Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-33846/ (Markdown: https://insights.sbomify.com/CVE-2021-33846/index.md)","id":"CVE-2021-33846","markdown":"https://insights.sbomify.com/CVE-2021-33846/index.md","name":"CVE-2021-33846","record":{"aliases":["GHSA-vvwm-gcgm-h9j6"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["account_takeover","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Infusion System Software","requires_auth":"high_privilege","summary":"An attacker with the symmetric key can forge JWTs to impersonate users in the Fresenius Kabi infusion system dashboard.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"agilia_connect_firmware","vendor":"fresenius-kabi"},{"product":"agilia_partner_maintenance_software","vendor":"fresenius-kabi"},{"product":"link\\+_agilia_firmware","vendor":"fresenius-kabi"},{"product":"vigilant_centerium","vendor":"fresenius-kabi"},{"product":"vigilant_insight","vendor":"fresenius-kabi"},{"product":"vigilant_mastermed","vendor":"fresenius-kabi"}],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-327","name":"Use of a Broken or Risky Cryptographic Algorithm"}],"description":"Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 issues authentication tokens to authenticated users that are signed with a symmetric encryption key. An attacker in possession of the key can issue valid JWTs and impersonate arbitrary users.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Fresenius Kabi Agilia Connect Infusion System use of a broken or risky cryptographic algorithm","id":"CVE-2021-33846","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in Intel(R) Wireless Bluetooth(R) and Killer(TM) Bluetooth(R) products","id":"CVE-2021-33847"},"packages":[],"prev":{"headline":"Username enumeration through lockout message in REST API","id":"CVE-2021-33845"},"products":["Vigilant Software Suite (Mastermed Dashboard)"],"published":"2022-01-21","related":[{"cvss_score":7.5,"headline":"Fresenius Kabi Agilia Connect Infusion System uncontrolled resource consumption","id":"CVE-2021-23236","kev_date_added":null,"published":"2022-01-21"},{"cvss_score":7.3,"headline":"Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials","id":"CVE-2021-23196","kev_date_added":null,"published":"2022-01-21"},{"cvss_score":7.3,"headline":"Fresenius Kabi Agilia Connect Infusion System","id":"CVE-2021-23233","kev_date_added":null,"published":"2022-01-21"},{"cvss_score":7.3,"headline":"Fresenius Kabi Agilia Connect Infusion System use of client side authentication","id":"CVE-2021-43355","kev_date_added":null,"published":"2022-01-21"},{"cvss_score":6.5,"headline":"Fresenius Kabi Agilia Connect Infusion System use of a broken or risky cryptographic algorithm","id":"CVE-2021-31562","kev_date_added":null,"published":"2022-01-21"},{"cvss_score":6.3,"headline":"Fresenius Kabi Agilia Connect Infusion System hard coded credentials","id":"CVE-2021-44464","kev_date_added":null,"published":"2022-01-21"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Fresenius Kabi"]},"summary":"An attacker with the symmetric key can forge JWTs to impersonate users in the Fresenius Kabi infusion system dashboard.","url":"https://insights.sbomify.com/CVE-2021-33846/"}