{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-36287 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-36287 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-36287 is a high-severity command injection vulnerability in Dell VNX2, published on 8 Apr 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-36287 and fix it if it is affected.\n\nWhat it is: CVE-2021-36287 is a high-severity command injection vulnerability in Dell VNX2, published on 8 Apr 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-36287 in the wild and no public exploit code.\n\nAffected product: Dell VNX2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-36287/ (Markdown: https://insights.sbomify.com/CVE-2021-36287/index.md)","id":"CVE-2021-36287","markdown":"https://insights.sbomify.com/CVE-2021-36287/index.md","name":"CVE-2021-36287","record":{"aliases":["GHSA-hwj9-m84w-q8mw"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Dell VNX2 storage","requires_auth":"none","summary":"Unauthenticated attackers can execute arbitrary commands on Dell VNX2 storage systems, leading to full system compromise.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"emc_unity_operating_environment","vendor":"dell"}],"cvss":{"score":7.3,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in VNX2","id":"CVE-2021-36287","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in VNX2","id":"CVE-2021-36288"},"packages":[],"prev":{"headline":"Path traversal in SupportAssist Client Consumer","id":"CVE-2021-36286"},"products":["VNX2"],"published":"2022-04-08","related":[{"cvss_score":9.8,"headline":"Auth bypass in VNX Control Station","id":"CVE-2021-36294","kev_date_added":null,"published":"2022-01-25"},{"cvss_score":8.6,"headline":"Path traversal in VNX2","id":"CVE-2021-36288","kev_date_added":null,"published":"2022-04-08"},{"cvss_score":7.8,"headline":"Information disclosure in VNX Control Station","id":"CVE-2021-36289","kev_date_added":null,"published":"2022-01-25"},{"cvss_score":7.8,"headline":"Information disclosure in Unity","id":"CVE-2019-3741","kev_date_added":null,"published":"2019-07-18"},{"cvss_score":7.8,"headline":"Privilege escalation in Dell EMC Unity","id":"CVE-2018-11064","kev_date_added":null,"published":"2018-10-05"},{"cvss_score":7.5,"headline":"Denial of service in Unity","id":"CVE-2020-29490","kev_date_added":null,"published":"2021-01-05"},{"cvss_score":7.5,"headline":"Denial of service in Unity","id":"CVE-2020-5319","kev_date_added":null,"published":"2020-02-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Dell"]},"summary":"Unauthenticated attackers can execute arbitrary commands on Dell VNX2 storage systems, leading to full system compromise.","url":"https://insights.sbomify.com/CVE-2021-36287/"}