{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-37161 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-37161 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-37161 is a critical memory corruption vulnerability in n/a, published on 2 Aug 2021. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-37161 and fix it if it is affected.\n\nWhat it is: CVE-2021-37161 is a critical memory corruption vulnerability in n/a, published on 2 Aug 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-37161 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-37161/ (Markdown: https://insights.sbomify.com/CVE-2021-37161/index.md)","id":"CVE-2021-37161","markdown":"https://insights.sbomify.com/CVE-2021-37161/index.md","name":"CVE-2021-37161","record":{"aliases":["GHSA-44g7-cc5h-5758"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Healthcare HMI panel","requires_auth":"none","summary":"A buffer overflow in the Swisslog Healthcare Nexus Panel allows attackers to overwrite internal data structures, leading to remote code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"hmi-3_control_panel_firmware","vendor":"swisslog-healthcare"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote code execution.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2021-37161","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2021"},"n_packages":0,"n_references":4,"next":{"headline":"Memory corruption in n/a","id":"CVE-2021-37162"},"packages":[],"prev":{"headline":"File upload in n/a","id":"CVE-2021-37160"},"products":["n/a"],"published":"2021-08-02","related":[{"cvss_score":9.8,"headline":"File upload in n/a","id":"CVE-2021-37160","kev_date_added":null,"published":"2021-08-02"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2021-37162","kev_date_added":null,"published":"2021-08-02"},{"cvss_score":9.8,"headline":"Hardcoded credentials in n/a","id":"CVE-2021-37163","kev_date_added":null,"published":"2021-08-02"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2021-37164","kev_date_added":null,"published":"2021-08-02"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2021-37165","kev_date_added":null,"published":"2021-08-02"},{"cvss_score":9.8,"headline":"Privilege escalation in n/a","id":"CVE-2021-37167","kev_date_added":null,"published":"2021-08-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"A buffer overflow in the Swisslog Healthcare Nexus Panel allows attackers to overwrite internal data structures, leading to remote code execution.","url":"https://insights.sbomify.com/CVE-2021-37161/"}