{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-37180 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-37180 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-37180 is a high-severity vulnerability in Siemens Solid Edge SE2021, published on 10 Aug 2021. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2021-37180 and fix it if it is affected.\n\nWhat it is: CVE-2021-37180 is a high-severity vulnerability in Siemens Solid Edge SE2021, published on 10 Aug 2021. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2021-37180 in the wild and no public exploit code.\n\nAffected product: Siemens Solid Edge SE2021. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-37180/ (Markdown: https://insights.sbomify.com/CVE-2021-37180/index.md)","id":"CVE-2021-37180","markdown":"https://insights.sbomify.com/CVE-2021-37180/index.md","name":"CVE-2021-37180","record":{"aliases":["GHSA-j2fm-87x9-h5c6"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens Solid Edge","requires_auth":"none","summary":"An attacker can execute arbitrary code by tricking a user into opening a malicious OBJ file in Siemens Solid Edge due to an uninitialized pointer access.","user_interaction":"required","vuln_class":"null_dereference"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"solid_edge_se2021_firmware","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-824","name":"Access of Uninitialized Pointer"}],"description":"A vulnerability has been identified in Solid Edge SE2021 (All Versions \u003c SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Null dereference in Solid Edge SE2021","id":"CVE-2021-37180","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"null_dereference","year":"2021"},"n_packages":0,"n_references":2,"next":{"headline":"Deserialization in Cerberus DMS V4.0","id":"CVE-2021-37181"},"packages":[],"prev":{"headline":"Use after free in Solid Edge SE2021","id":"CVE-2021-37179"},"products":["Solid Edge SE2021"],"published":"2021-08-10","related":[{"cvss_score":7.8,"headline":"Use after free in Solid Edge SE2021","id":"CVE-2021-37179","kev_date_added":null,"published":"2021-08-10"},{"cvss_score":5.5,"headline":"XML external entity in Solid Edge SE2021","id":"CVE-2021-37178","kev_date_added":null,"published":"2021-08-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"An attacker can execute arbitrary code by tricking a user into opening a malicious OBJ file in Siemens Solid Edge due to an uninitialized pointer access.","url":"https://insights.sbomify.com/CVE-2021-37180/"}