{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-37194 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-37194 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-37194 is a high-severity vulnerability in Siemens COMOS V10.2, published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-37194 and fix it if it is affected.\n\nWhat it is: CVE-2021-37194 is a high-severity vulnerability in Siemens COMOS V10.2, published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-37194 in the wild and no public exploit code.\n\nAffected product: Siemens COMOS V10.2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-37194/ (Markdown: https://insights.sbomify.com/CVE-2021-37194/index.md)","id":"CVE-2021-37194","markdown":"https://insights.sbomify.com/CVE-2021-37194/index.md","name":"CVE-2021-37194","record":{"aliases":["GHSA-3pr9-fm6f-mq6g"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":true,"product_category":"Siemens COMOS","requires_auth":"none","summary":"Attackers can upload malicious files to the Siemens COMOS web server if web components are enabled, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"comos","vendor":"siemens"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"}],"description":"A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions \u003c V10.3.3.3 only if web components are used), COMOS V10.4 (All versions \u003c V10.4.1 only if web components are used). The COMOS Web component of COMOS allows to upload and store arbitrary files at the webserver. This could allow an attacker to store malicious files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"File upload in COMOS V10.2","id":"CVE-2021-37194","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in COMOS V10.2","id":"CVE-2021-37195"},"packages":[],"prev":{"headline":"Business logic in SINEMA Remote Connect Server","id":"CVE-2021-37193"},"products":["COMOS V10.2","COMOS V10.3","COMOS V10.4"],"published":"2022-02-09","related":[{"cvss_score":10,"headline":"Memory corruption in COMOS V10.2","id":"CVE-2023-24482","kev_date_added":null,"published":"2023-02-14"},{"cvss_score":9.6,"headline":"Memory corruption in COMOS","id":"CVE-2023-43504","kev_date_added":null,"published":"2023-11-14"},{"cvss_score":9.6,"headline":"Missing authorization in COMOS","id":"CVE-2023-43505","kev_date_added":null,"published":"2023-11-14"},{"cvss_score":9.6,"headline":"Missing authorization in COMOS","id":"CVE-2023-46601","kev_date_added":null,"published":"2023-11-14"},{"cvss_score":8.8,"headline":"SQL injection in COMOS V10.2","id":"CVE-2021-37197","kev_date_added":null,"published":"2022-01-11"},{"cvss_score":8.8,"headline":"Cross-site request forgery in COMOS V10.2","id":"CVE-2021-37198","kev_date_added":null,"published":"2022-01-11"},{"cvss_score":8.5,"headline":"Privilege escalation in n/a","id":"CVE-2012-3009","kev_date_added":null,"published":"2012-08-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"Attackers can upload malicious files to the Siemens COMOS web server if web components are enabled, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2021-37194/"}