{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2021-38398 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-38398 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-38398 is a medium-severity vulnerability in Boston Scientific ZOOM LATITUDE, published on 4 Oct 2021. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2021-38398 and fix it if it is affected.\n\nWhat it is: CVE-2021-38398 is a medium-severity vulnerability in Boston Scientific ZOOM LATITUDE, published on 4 Oct 2021. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2021-38398 in the wild and no public exploit code.\n\nAffected product: Boston Scientific ZOOM LATITUDE. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-38398/ (Markdown: https://insights.sbomify.com/CVE-2021-38398/index.md)","id":"CVE-2021-38398","markdown":"https://insights.sbomify.com/CVE-2021-38398/index.md","name":"CVE-2021-38398","record":{"aliases":["GHSA-95jv-vw56-8f6x"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device","requires_auth":"none","summary":"Attackers with physical access can exploit unpatched vulnerabilities in outdated third-party components within the Boston Scientific ZOOM LATITUDE device.","user_interaction":"required","vuln_class":"supply_chain"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"zoom_latitude_pogrammer\\/recorder\\/monitor_3120_firmware","vendor":"bostonscientific"},{"product":"zoom_latitude_programming_system_model_3120_firmware","vendor":"bostonscientific"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-1329","name":"Reliance on Component That is Not Updateable"}],"description":"The affected device uses off-the-shelf software components that contain unpatched vulnerabilities. A malicious attacker with physical access to the affected device could exploit these vulnerabilities.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Reliance on Component that is not Updateable for Boston Scientific Zoom Latitude","id":"CVE-2021-38398","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"supply_chain","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Honeywell Experion PKS and ACE Controllers Relative Path Traversal","id":"CVE-2021-38399"},"packages":[],"prev":{"headline":"Honeywell Experion PKS and ACE Controllers Unrestricted Upload of File with Dangerous Type","id":"CVE-2021-38397"},"products":["ZOOM LATITUDE"],"published":"2021-10-04","related":[{"cvss_score":6.9,"headline":"Use of Password Hash with Insufficient Computational Effort for Boston Scientific Zoom Latitude","id":"CVE-2021-38400","kev_date_added":null,"published":"2021-10-04"},{"cvss_score":6.5,"headline":"Improper Access Control for Boston Scientific Zoom Latitude","id":"CVE-2021-38392","kev_date_added":null,"published":"2021-10-04"},{"cvss_score":6.5,"headline":"Missing Support Integrity Check for Boston Scientific Zoom Latitude","id":"CVE-2021-38396","kev_date_added":null,"published":"2021-10-04"},{"cvss_score":6.2,"headline":"Security feature bypass in ZOOM LATITUDE","id":"CVE-2021-38394","kev_date_added":null,"published":"2021-10-04"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Boston Scientific"]},"summary":"Attackers with physical access can exploit unpatched vulnerabilities in outdated third-party components within the Boston Scientific ZOOM LATITUDE device.","url":"https://insights.sbomify.com/CVE-2021-38398/"}