{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-40222 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-40222 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-40222 is a high-severity command injection vulnerability in n/a, published on 9 Sep 2021. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-40222 and fix it if it is affected.\n\nWhat it is: CVE-2021-40222 is a high-severity command injection vulnerability in n/a, published on 9 Sep 2021. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-40222 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-40222/ (Markdown: https://insights.sbomify.com/CVE-2021-40222/index.md)","id":"CVE-2021-40222","markdown":"https://insights.sbomify.com/CVE-2021-40222/index.md","name":"CVE-2021-40222","record":{"aliases":["GHSA-cxf9-4ff5-hx4j"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Rittal CMC PU III","requires_auth":"high_privilege","summary":"Remote attackers can inject shell commands via the hostname field to execute code as root on Rittal CMC PU III devices.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"cmc_pu_iii_7030.000_firmware","vendor":"rittal"}],"cvss":{"score":7.2,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Rittal CMC PU III Web management Version affected: V3.11.00_2. Version fixed: V3.17.10 is affected by a remote code execution vulnerablity. It is possible to introduce shell code to create a reverse shell in the PU-Hostname field of the TCP/IP Configuration dialog. Web application fails to sanitize user input on Network TCP/IP configuration page. This allows the attacker to inject commands as root on the device which will be executed once the data is received.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2021-08-04","github_poc":1,"max_poc_stars":0,"metasploit":0,"nuclei":0,"refs":[{"date":"2021-08-04T16:10:05Z","kind":"github_poc","ref":"https://github.com/asang17/CVE-2021-40222","stars":0,"title":"Remote Code Execution at Rittal"}],"tier":"poc_unverified"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2021-40222","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2021-40223"},"packages":[],"prev":{"headline":"Code Injection in Bolt CMS","id":"CVE-2021-40219"},"products":["n/a"],"published":"2021-09-09","related":[{"cvss_score":6.1,"headline":"Cross-site scripting in n/a","id":"CVE-2019-19393","kev_date_added":null,"published":"2020-10-01"},{"cvss_score":5.4,"headline":"Cross-site scripting in n/a","id":"CVE-2021-40223","kev_date_added":null,"published":"2021-09-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"open","licence":"CC0","name":"PoC-in-GitHub"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Remote attackers can inject shell commands via the hostname field to execute code as root on Rittal CMC PU III devices.","url":"https://insights.sbomify.com/CVE-2021-40222/"}