{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2021-41301 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-41301 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-41301 is a critical vulnerability in ECOA ECS Router Controller ECS (FLASH), published on 30 Sep 2021. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-41301 and fix it if it is affected.\n\nWhat it is: CVE-2021-41301 is a critical vulnerability in ECOA ECS Router Controller ECS (FLASH), published on 30 Sep 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-41301 in the wild and no public exploit code.\n\nAffected product: ECOA ECS Router Controller ECS (FLASH). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-41301/ (Markdown: https://insights.sbomify.com/CVE-2021-41301/index.md)","id":"CVE-2021-41301","markdown":"https://insights.sbomify.com/CVE-2021-41301/index.md","name":"CVE-2021-41301","record":{"aliases":["GHSA-2qv4-869g-77jr"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"ECOA BAS controller","requires_auth":"none","summary":"Unauthenticated attackers can access sensitive configuration files via direct object reference, leading to information disclosure and potential system compromise.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"twcert","cpe":[{"product":"ecs_router_controller-ecs_firmware","vendor":"ecoa"},{"product":"riskbuster_firmware","vendor":"ecoa"},{"product":"riskterminator","vendor":"ecoa"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-639","name":"Authorization Bypass Through User-Controlled Key"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"ECOA BAS controller is vulnerable to configuration disclosure when direct object reference is made to the specific files using an HTTP GET request. This will enable the unauthenticated attacker to remotely disclose sensitive information and help her in authentication bypass, privilege escalation and full system access.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"ECOA BAS controller - Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2021-41301","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"ECOA BAS controller - Missing Encryption of Sensitive Data","id":"CVE-2021-41302"},"packages":[],"prev":{"headline":"ECOA BAS controller - Insufficiently Protected Credentials-2","id":"CVE-2021-41300"},"products":["ECS Router Controller ECS (FLASH)","Graphic Control Software","RiskBuster System RB 3.0.0","RiskBuster System TRANE 1.0","RiskBuster Terminator E6L45","RiskTerminator","SmartHome II E9246"],"published":"2021-09-30","related":[{"cvss_score":9.8,"headline":"ECOA BAS controller - Path Traversal-1","id":"CVE-2021-41290","kev_date_added":null,"published":"2021-09-30"},{"cvss_score":9.8,"headline":"ECOA BAS controller - Broken Authentication","id":"CVE-2021-41292","kev_date_added":null,"published":"2021-09-30"},{"cvss_score":9.8,"headline":"ECOA BAS controller - Weak Password Requirements","id":"CVE-2021-41296","kev_date_added":null,"published":"2021-09-30"},{"cvss_score":9.8,"headline":"ECOA BAS controller - Use of Hard-coded Credentials","id":"CVE-2021-41299","kev_date_added":null,"published":"2021-09-30"},{"cvss_score":9.8,"headline":"ECOA BAS controller - Insufficiently Protected Credentials-2","id":"CVE-2021-41300","kev_date_added":null,"published":"2021-09-30"},{"cvss_score":9.1,"headline":"ECOA BAS controller - Path Traversal-4","id":"CVE-2021-41294","kev_date_added":null,"published":"2021-09-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["ECOA"]},"summary":"Unauthenticated attackers can access sensitive configuration files via direct object reference, leading to information disclosure and potential system compromise.","url":"https://insights.sbomify.com/CVE-2021-41301/"}