High 7.5 Published Updated

Improper input validation in Siemens SIPROTEC 5 devices allows attackers to cause a denial of service condition.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2021-41769?

CVE-2021-41769 is a high-severity vulnerability in Siemens SIPROTEC 5 6MD85 devices (CPU variant CP300), published on 11 Jan 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.

Weakness: CWE-20

Which versions are affected by CVE-2021-41769?

It affects 31 products.

Products include Siemens 6md85 Firmware, Siemens 6md86 Firmware, Siemens 6md89 Firmware, Siemens 6mu85 Firmware, Siemens 7ke85 Firmware, Siemens 7sa82 Firmware and 25 more.

How do I fix CVE-2021-41769?

No fix has been published for CVE-2021-41769 yet. Limit exposure of the affected software until one is available.

Is CVE-2021-41769 being exploited?

There is no known exploitation of CVE-2021-41769 in the wild and no public exploit code.