{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2021-42744 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-42744 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-42744 is a medium-severity vulnerability in Philips MRI 1.5T, published on 19 Nov 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-42744 and fix it if it is affected.\n\nWhat it is: CVE-2021-42744 is a medium-severity vulnerability in Philips MRI 1.5T, published on 19 Nov 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-42744 in the wild and no public exploit code.\n\nAffected product: Philips MRI 1.5T. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-42744/ (Markdown: https://insights.sbomify.com/CVE-2021-42744/index.md)","id":"CVE-2021-42744","markdown":"https://insights.sbomify.com/CVE-2021-42744/index.md","name":"CVE-2021-42744","record":{"aliases":["GHSA-8mp4-2m2j-25xx"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical imaging device","requires_auth":"none","summary":"Unauthorized actors can access restricted resources on Philips MRI systems, leading to potential information exposure.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"mri_1.5t_firmware","vendor":"philips"},{"product":"mri_3t_firmware","vendor":"philips"}],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-552","name":"Files or Directories Accessible to External Parties"}],"description":"Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips MRI 1.5T and 3T Information Exposure","id":"CVE-2021-42744","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2021"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in n/a","id":"CVE-2021-42748"},"packages":[],"prev":{"headline":"Local privilege escalation via a default path in Splunk Enterprise Windows","id":"CVE-2021-42743"},"products":["MRI 1.5T","MRI 3T"],"published":"2021-11-19","related":[{"cvss_score":5.9,"headline":"Philips MRI 1.5T and 3T Incorrect Ownership Assignment","id":"CVE-2021-26248","kev_date_added":null,"published":"2021-11-19"},{"cvss_score":5.9,"headline":"Philips MRI 1.5T and 3T Improper Access Control","id":"CVE-2021-26262","kev_date_added":null,"published":"2021-11-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2026-04-02","vendors":["Philips"]},"summary":"Unauthorized actors can access restricted resources on Philips MRI systems, leading to potential information exposure.","url":"https://insights.sbomify.com/CVE-2021-42744/"}