{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2021-43548 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-43548 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-43548 is a medium-severity vulnerability in Philips Patient Information Center iX (PIC iX), published on 27 Dec 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-43548 and fix it if it is affected.\n\nWhat it is: CVE-2021-43548 is a medium-severity vulnerability in Philips Patient Information Center iX (PIC iX), published on 27 Dec 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-43548 in the wild and no public exploit code.\n\nAffected product: Philips Patient Information Center iX (PIC iX). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-43548/ (Markdown: https://insights.sbomify.com/CVE-2021-43548/index.md)","id":"CVE-2021-43548","markdown":"https://insights.sbomify.com/CVE-2021-43548/index.md","name":"CVE-2021-43548","record":{"aliases":["GHSA-vqqw-576h-989f"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["other"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device software","requires_auth":"none","summary":"Philips medical devices fail to properly validate input, potentially allowing attackers to disrupt operations or cause undefined behavior.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"patient_information_center_ix","vendor":"philips"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation","id":"CVE-2021-43548","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"OSIsoft PI Web API","id":"CVE-2021-43549"},"packages":[],"prev":{"headline":"TwinOaks Computing CoreDX DDS Secure Network Amplification","id":"CVE-2021-43547"},"products":["Patient Information Center iX (PIC iX)"],"published":"2021-12-27","related":[{"cvss_score":8.8,"headline":"Philips Patient Monitoring Devices Improper Authentication","id":"CVE-2020-16222","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":6.8,"headline":"Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere","id":"CVE-2020-16212","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":6.5,"headline":"Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency","id":"CVE-2020-16224","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":6.1,"headline":"Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key","id":"CVE-2021-43552","kev_date_added":null,"published":"2021-12-27"},{"cvss_score":5,"headline":"Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV File","id":"CVE-2020-16214","kev_date_added":null,"published":"2020-09-11"},{"cvss_score":4.3,"headline":"Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input","id":"CVE-2020-16220","kev_date_added":null,"published":"2020-09-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Philips"]},"summary":"Philips medical devices fail to properly validate input, potentially allowing attackers to disrupt operations or cause undefined behavior.","url":"https://insights.sbomify.com/CVE-2021-43548/"}