{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2021-44165 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2021-44165 yet. Limit exposure of the affected software until one is available.","what":"CVE-2021-44165 is a high-severity memory corruption vulnerability in Siemens POWER METER SICAM Q100, published on 14 Dec 2021. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2021-44165 and fix it if it is affected.\n\nWhat it is: CVE-2021-44165 is a high-severity memory corruption vulnerability in Siemens POWER METER SICAM Q100, published on 14 Dec 2021. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2021-44165 in the wild and no public exploit code.\n\nAffected product: Siemens POWER METER SICAM Q100. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2021-44165/ (Markdown: https://insights.sbomify.com/CVE-2021-44165/index.md)","id":"CVE-2021-44165","markdown":"https://insights.sbomify.com/CVE-2021-44165/index.md","name":"CVE-2021-44165","record":{"aliases":["GHSA-rwp6-cpw3-hxxx"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens power meter","requires_auth":"high_privilege","summary":"A buffer overflow in the web application allows remote attackers with engineer or admin privileges to execute arbitrary code on Siemens SICAM Q100 power meters.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kg9501-0aa01-0aa1_firmware","vendor":"siemens"},{"product":"7kg9501-0aa01-2aa1_firmware","vendor":"siemens"},{"product":"7kg9501-0aa31-0aa1_firmware","vendor":"siemens"},{"product":"7kg9501-0aa31-2aa1_firmware","vendor":"siemens"}],"cvss":{"score":7.2,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in POWER METER SICAM Q100","id":"CVE-2021-44165","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2021"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in Fortinet FortiTokenAndroid","id":"CVE-2021-44166"},"packages":[],"prev":{"headline":"Chain Sea Information Integration Co., Ltd ai chatbot system - Arbitrary File Upload","id":"CVE-2021-44164"},"products":["POWER METER SICAM Q100"],"published":"2021-12-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"A buffer overflow in the web application allows remote attackers with engineer or admin privileges to execute arbitrary code on Siemens SICAM Q100 power meters.","url":"https://insights.sbomify.com/CVE-2021-44165/"}