{"answers":{"affected":"It affects 33 products.","exploited":"There is no known exploitation of CVE-2022-0715 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-0715 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-0715 is a high-severity authentication bypass vulnerability in Schneider Electric APC Smart-UPS, published on 9 Mar 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-0715 and fix it if it is affected.\n\nWhat it is: CVE-2022-0715 is a high-severity authentication bypass vulnerability in Schneider Electric APC Smart-UPS, published on 9 Mar 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-0715 in the wild and no public exploit code.\n\nAffected product: Schneider Electric APC Smart-UPS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-0715/ (Markdown: https://insights.sbomify.com/CVE-2022-0715/index.md)","id":"CVE-2022-0715","markdown":"https://insights.sbomify.com/CVE-2022-0715/index.md","name":"CVE-2022-0715","record":{"aliases":["GHSA-fxwp-hqgp-45qg"],"analysis":{"component_type":"hardware_firmware","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"APC Smart-UPS","requires_auth":"none","summary":"Attackers can upload malicious firmware to APC Smart-UPS devices by exploiting improper authentication when a key is leaked, leading to arbitrary behavior changes.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"scl_series_1029_ups_firmware","vendor":"schneider-electric"},{"product":"scl_series_1030_ups_firmware","vendor":"schneider-electric"},{"product":"scl_series_1036_ups_firmware","vendor":"schneider-electric"},{"product":"scl_series_1037_ups_firmware","vendor":"schneider-electric"},{"product":"smc_series_1005_ups_firmware","vendor":"schneider-electric"},{"product":"smc_series_1007_ups_firmware","vendor":"schneider-electric"},{"product":"smc_series_1018_ups_firmware","vendor":"schneider-electric"},{"product":"smc_series_1041_ups_firmware","vendor":"schneider-electric"},{"product":"smt_series_1015_ups_firmware","vendor":"schneider-electric"},{"product":"smt_series_1031_ups_firmware","vendor":"schneider-electric"},{"product":"smt_series_1040_ups_firmware","vendor":"schneider-electric"},{"product":"smt_series_18_ups_firmware","vendor":"schneider-electric"},{"product":"smtl_series_1026_ups_firmware","vendor":"schneider-electric"},{"product":"smx_series_1031_ups_firmware","vendor":"schneider-electric"},{"product":"smx_series_20_ups_firmware","vendor":"schneider-electric"},{"product":"smx_series_23_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1001_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1002_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1010_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1013_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1014_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1019_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1020_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1021_ups_firmware","vendor":"schneider-electric"},{"product":"srt_series_1025_ups_firmware","vendor":"schneider-electric"},{"product":"srtl1000rmxli-nc_firmware","vendor":"schneider-electric"},{"product":"srtl1000rmxli_firmware","vendor":"schneider-electric"},{"product":"srtl1500rmxli-nc_firmware","vendor":"schneider-electric"},{"product":"srtl1500rmxli_firmware","vendor":"schneider-electric"},{"product":"srtl2200rmxli-nc_firmware","vendor":"schneider-electric"},{"product":"srtl2200rmxli_firmware","vendor":"schneider-electric"},{"product":"srtl3000rmxli-nc_firmware","vendor":"schneider-electric"},{"product":"srtl3000rmxli_firmware","vendor":"schneider-electric"}],"cvss":{"score":8.9,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"},{"id":"CWE-287","name":"Improper Authentication"}],"description":"A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in APC Smart-UPS","id":"CVE-2022-0715","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Out-of-bounds Read in mruby/mruby","id":"CVE-2022-0717"},"packages":[],"prev":{"headline":"Heap-based Buffer Overflow in vim/vim","id":"CVE-2022-0714"},"products":["APC Smart-UPS","SmartConnect"],"published":"2022-03-09","related":[{"cvss_score":9.8,"headline":"Memory corruption in SmartConnect","id":"CVE-2022-22805","kev_date_added":null,"published":"2022-03-09"},{"cvss_score":9.8,"headline":"Auth bypass in SmartConnect","id":"CVE-2022-22806","kev_date_added":null,"published":"2022-03-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-29","vendors":["Schneider Electric"]},"summary":"Attackers can upload malicious firmware to APC Smart-UPS devices by exploiting improper authentication when a key is leaked, leading to arbitrary behavior changes.","url":"https://insights.sbomify.com/CVE-2022-0715/"}