{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-0922 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-0922 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-0922 is a medium-severity missing authorization vulnerability in Philips e-Alert, published on 1 Apr 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-0922 and fix it if it is affected.\n\nWhat it is: CVE-2022-0922 is a medium-severity missing authorization vulnerability in Philips e-Alert, published on 1 Apr 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-0922 in the wild and no public exploit code.\n\nAffected product: Philips e-Alert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-0922/ (Markdown: https://insights.sbomify.com/CVE-2022-0922/index.md)","id":"CVE-2022-0922","markdown":"https://insights.sbomify.com/CVE-2022-0922/index.md","name":"CVE-2022-0922","record":{"aliases":["GHSA-jqvg-r3v8-55fm"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips e-Alert system","requires_auth":"none","summary":"Attackers can access critical system functionality without authentication, potentially leading to unauthorized control or data modification in Philips e-Alert systems.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"e-alert_firmware","vendor":"philips"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"The software does not perform any authentication for critical system functionality.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"ICSMA-22-088-01 Philips e-Alert","id":"CVE-2022-0922","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Delta Electronics DIAEnergie SQL Injection in HandlerDialog_KID.ashx","id":"CVE-2022-0923"},"packages":[],"prev":{"headline":"Abusing Backup/Restore feature to achieve Remote Code Execution in microweber/microweber","id":"CVE-2022-0921"},"products":["e-Alert"],"published":"2022-04-01","related":[{"cvss_score":9.8,"headline":"Code injection in e-Alert Unit (non-medical device)","id":"CVE-2018-8850","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":9.8,"headline":"Hardcoded credentials in e-Alert Unit (non-medical device)","id":"CVE-2018-8856","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":8.8,"headline":"Information disclosure in e-Alert Unit (non-medical device)","id":"CVE-2018-8842","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":8.8,"headline":"Cross-site request forgery in e-Alert Unit (non-medical device)","id":"CVE-2018-8844","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":8.8,"headline":"Auth bypass in e-Alert Unit (non-medical device)","id":"CVE-2018-8852","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":7.5,"headline":"Misconfiguration in e-Alert Unit (non-medical device)","id":"CVE-2018-8848","kev_date_added":null,"published":"2018-09-26"},{"cvss_score":7.5,"headline":"Denial of service in e-Alert Unit (non-medical device)","id":"CVE-2018-8854","kev_date_added":null,"published":"2018-09-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Philips"]},"summary":"Attackers can access critical system functionality without authentication, potentially leading to unauthorized control or data modification in Philips e-Alert systems.","url":"https://insights.sbomify.com/CVE-2022-0922/"}