{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-1368 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-1368 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-1368 is a critical missing authorization vulnerability in Cognex 3D-A1000 Dimensioning System, published on 6 Sep 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-1368 and fix it if it is affected.\n\nWhat it is: CVE-2022-1368 is a critical missing authorization vulnerability in Cognex 3D-A1000 Dimensioning System, published on 6 Sep 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-1368 in the wild and no public exploit code.\n\nAffected product: Cognex 3D-A1000 Dimensioning System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-1368/ (Markdown: https://insights.sbomify.com/CVE-2022-1368/index.md)","id":"CVE-2022-1368","markdown":"https://insights.sbomify.com/CVE-2022-1368/index.md","name":"CVE-2022-1368","record":{"aliases":["GHSA-j7fp-3pf5-h6cj"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Cognex 3D-A1000","requires_auth":"none","summary":"Unauthenticated attackers can change operator passwords via web socket monitoring, leading to privilege escalation on Cognex 3D-A1000 systems.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"3d-a1000_dimensioning_system_firmware","vendor":"cognex"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function","id":"CVE-2022-1368","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND.","id":"CVE-2022-1369"},"packages":[],"prev":{"headline":"SQL injection in DIAEnergie","id":"CVE-2022-1367"},"products":["3D-A1000 Dimensioning System"],"published":"2022-09-06","related":[{"cvss_score":9.1,"headline":"Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security","id":"CVE-2022-1525","kev_date_added":null,"published":"2022-09-06"},{"cvss_score":5.3,"headline":"Cognex 3D-A1000 Dimensioning System Improper Output Neutralization for Logs","id":"CVE-2022-1522","kev_date_added":null,"published":"2022-09-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Cognex"]},"summary":"Unauthenticated attackers can change operator passwords via web socket monitoring, leading to privilege escalation on Cognex 3D-A1000 systems.","url":"https://insights.sbomify.com/CVE-2022-1368/"}