{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-1778 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-1778 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-1778 is a high-severity memory corruption vulnerability in Hitachi Energy MicroSCADA X SYS600, published on 14 Sep 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-1778 and fix it if it is affected.\n\nWhat it is: CVE-2022-1778 is a high-severity memory corruption vulnerability in Hitachi Energy MicroSCADA X SYS600, published on 14 Sep 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-1778 in the wild and no public exploit code.\n\nAffected product: Hitachi Energy MicroSCADA X SYS600. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-1778/ (Markdown: https://insights.sbomify.com/CVE-2022-1778/index.md)","id":"CVE-2022-1778","markdown":"https://insights.sbomify.com/CVE-2022-1778/index.md","name":"CVE-2022-1778","record":{"aliases":["GHSA-84rx-9qxm-ffcf"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA system","requires_auth":"none","summary":"An input validation flaw in Hitachi Energy MicroSCADA X SYS600 causes a buffer overflow during startup, leading to a denial of service.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Hitachi Energy","cpe":[{"product":"microscada_x_sys600","vendor":"hitachienergy"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in MicroSCADA X SYS600","id":"CVE-2022-1778","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Auto Delete Posts \u003c= 1.3.0 - Arbitrary Settings Update via CSRF","id":"CVE-2022-1779"},"packages":[],"prev":{"headline":"Filr - Secure Document Library \u003c 1.2.2.1 - Subscriber+ AJAX Calls","id":"CVE-2022-1777"},"products":["MicroSCADA X SYS600"],"published":"2022-09-14","related":[{"cvss_score":8.5,"headline":"Missing authorization in MicroSCADA SYS600","id":"CVE-2026-9853","kev_date_added":null,"published":"2026-09-03"},{"cvss_score":8.5,"headline":"Privilege escalation in MicroSCADA SYS600","id":"CVE-2026-9854","kev_date_added":null,"published":"2026-09-03"},{"cvss_score":8.5,"headline":"Information disclosure in MicroSCADA X SYS600","id":"CVE-2025-39204","kev_date_added":null,"published":"2025-06-24"},{"cvss_score":8.5,"headline":"Missing authorization in MicroSCADA X SYS600","id":"CVE-2022-29490","kev_date_added":null,"published":"2022-09-12"},{"cvss_score":8.3,"headline":"Missing authorization in MicroSCADA X SYS600","id":"CVE-2025-39202","kev_date_added":null,"published":"2025-06-24"},{"cvss_score":8.3,"headline":"Missing authorization in MicroSCADA SYS600","id":"CVE-2024-7940","kev_date_added":null,"published":"2024-08-27"},{"cvss_score":8.2,"headline":"Auth bypass in MicroSCADA SYS600","id":"CVE-2024-3982","kev_date_added":null,"published":"2024-08-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Hitachi Energy"]},"summary":"An input validation flaw in Hitachi Energy MicroSCADA X SYS600 causes a buffer overflow during startup, leading to a denial of service.","url":"https://insights.sbomify.com/CVE-2022-1778/"}